Main Content

pid2

2-DOF PID controller in parallel form

Description

Use pid2 to create parallel-form, two-degree-of-freedom (2-DOF) proportional-integral-derivative (PID) controller model objects, or to convert dynamic system models to parallel 2-DOF PID controller form.

2-DOF PID controllers include setpoint weighting on the proportional and derivative terms. A 2-DOF PID controller can achieve fast disturbance rejection without significant increase of overshoot in setpoint tracking. 2-DOF PID controllers are also useful to mitigate the influence of changes in the reference signal on the control signal. The following illustration shows a typical control architecture using a 2-DOF PID controller.

The pid2 controller model object can represent parallel-form PID controllers in continuous time or discrete time.

  • Continuous time — u=Kp(bry)+Kis(ry)+KdsTfs+1(cry)

  • Discrete time — u=Kp(bry)+KiIF(z)(ry)+KdTf+DF(z)(cry)

Here:

  • b is the setpoint weighting on the proportional term.

  • c is the setpoint weighting on the derivative term.

  • Kp is the proportional gain.

  • Ki is the integral gain.

  • Kd is the derivative gain.

  • Tf is the first-order derivative filter time constant.

  • IF(z) is the integrator method for computing the integral in the discrete-time controller.

  • DF(z) is the integrator method for computing the derivative filter in the discrete-time controller.

You can then combine this object with other components of a control architecture, such as the plant, actuators, and sensors to represent your control system. For more information, see Control System Modeling with Model Objects.

You can create a PID controller model object by either specifying the controller parameters directly, or by converting a model of another type (such as a transfer function model tf) to PID controller form.

You can also use pid2 to create generalized state-space (genss) models or uncertain state-space (uss (Robust Control Toolbox)) models.

Creation

You can obtain pid2 controller models in one of the following ways.

  • Create a model using the pid2 function.

  • Use the pidtune function to tune PID controllers for a plant model. Specify a 2-DOF PID controller type in the type argument of the pidtune function to obtain a parallel-form 2-DOF PID controller. For example:

    sys = zpk([],[-1 -1 -1],1);
    C2 = pidtune(sys,'PID2');
  • Interactively tune the PID controller for a plant model using:

Description

C2 = pid2(Kp,Ki,Kd,Tf,b,c) creates a continuous-time 2-DOF parallel-form PID controller model and sets the properties Kp, Ki, Kd, Tf, b, and c. The remaining properties have default values.

example

C2 = pid2(Kp,Ki,Kd,Tf,b,c,Ts) creates a discrete-time 2-DOF PID controller model with sample time Ts.

example

C2 = pid2(___,Name,Value) sets properties of the pid2 controller object specified using one or more Name,Value arguments for any of the previous input-argument combinations.

example

C2 = pid2 creates a controller object with default property values. To modify the property of the controller model, use dot notation.

example

C2 = pid2(sys) converts the dynamic system model sys to a parallel-form pid2 controller object.

example

Input Arguments

expand all

Proportional gain, specified as a real and finite value or a tunable object.

  • To create a pid2 controller object, use a real and finite scalar value.

  • To create an array of pid2 controller objects, use an array of real and finite values.

  • To create a tunable controller model, use a tunable parameter (realp) or generalized matrix (genmat).

  • To create a tunable gain-scheduled controller model, use a tunable surface created using tunableSurface.

Integral gain, specified as a real and finite value or a tunable object.

  • To create a pid2 controller object, use a real and finite scalar value.

  • To create an array of pid2 controller objects, use an array of real and finite values.

  • To create a tunable controller model, use a tunable parameter (realp) or generalized matrix (genmat).

  • To create a tunable gain-scheduled controller model, use a tunable surface created using tunableSurface.

Derivative gain, specified as a real and finite value or a tunable object.

  • To create a pid2 controller object, use a real and finite scalar value.

  • To create an array of pid2 controller objects, use an array of real and finite values.

  • To create a tunable controller model, use a tunable parameter (realp) or generalized matrix (genmat).

  • To create a tunable gain-scheduled controller model, use a tunable surface created using tunableSurface.

Time constant of the first-order derivative filter, specified as a real and finite value or a tunable object.

  • To create a pid2 controller object, use a real and finite scalar value.

  • To create an array of pid2 controller objects, use an array of real and finite values.

  • To create a tunable controller model, use a tunable parameter (realp) or generalized matrix (genmat).

  • To create a tunable gain-scheduled controller model, use a tunable surface created using tunableSurface.

Setpoint weighting on the proportional term, specified as a real and finite value or a tunable object.

  • To create a pid2 controller object, use a real and finite scalar value.

  • To create an array of pid2 controller objects, use an array of real and finite values.

  • To create a tunable controller model, use a tunable parameter (realp) or generalized matrix (genmat).

  • To create a tunable gain-scheduled controller model, use a tunable surface created using tunableSurface.

When b = 0, changes in setpoint do not feed directly into the proportional term.

Setpoint weighting on the derivative term, specified as a real and finite value or a tunable object.

  • To create a pid2 controller object, use a real and finite scalar value.

  • To create an array of pid2 controller objects, use an array of real and finite values.

  • To create a tunable controller model, use a tunable parameter (realp) or generalized matrix (genmat).

  • To create a tunable gain-scheduled controller model, use a tunable surface created using tunableSurface.

When c = 0, changes in setpoint do not feed directly into the derivative term.

Sample time, specified as:

  • 0 for continuous-time systems.

  • A positive scalar representing the sampling period of a discrete-time system. Specify Ts in the time unit specified by the TimeUnit property.

In an array of pid2 controllers, the same Ts applies to all controllers.

PID controller models do not support unspecified sample time (Ts = -1).

Note

Changing Ts does not discretize or resample the model. To convert between continuous-time and discrete-time representations, use c2d and d2c. To change the sample time of a discrete-time system, use d2d.

The discrete integrator formulas of the discretized controller depend upon the c2d discretization method you use, as shown in this table.

c2d Discretization MethodIFormulaDFormula
'zoh'ForwardEulerForwardEuler
'foh'TrapezoidalTrapezoidal
'tustin'TrapezoidalTrapezoidal
'impulse'ForwardEulerForwardEuler
'matched'ForwardEulerForwardEuler

For more information about c2d discretization methods, see c2d.

If you require different discrete integrator formulas, you can discretize the controller by directly setting Ts, IFormula, and DFormula to the desired values. However, this method does not compute new gain and filter-constant values for the discretized controller. Therefore, this method might yield a poorer match between the continuous-time and discrete-time PID controllers than using c2d.

Dynamic system, specified as a SISO dynamic system model or array of SISO dynamic system models. Dynamic systems that you can use include:

  • Continuous-time or discrete-time numeric LTI models, such as tf, zpk, ss, or pidstd models.

  • Generalized or uncertain LTI models such as genss or uss (Robust Control Toolbox) models.

    The resulting PID controller assumes:

    • Current values of the tunable components for tunable control design blocks.

    • Nominal model values for uncertain control design blocks.

  • Identified LTI models, such as idtf (System Identification Toolbox), idss (System Identification Toolbox), idproc (System Identification Toolbox), idpoly (System Identification Toolbox), and idgrey (System Identification Toolbox) models.

Output Arguments

expand all

PID controller model, returned as:

  • A 2-DOF parallel-form PID controller (pid2) model object, when all the gains have numeric values.

  • If one or more coefficients is a numeric array, C2 is an array of pid2 controller objects. The controller type (such as PI, PID, or PDF) depends upon the values of the gains. For example, when Td = 0, but Kp and Ti are nonzero and finite, C2 is a PI controller.

  • If one or more coefficients is a tunable parameter (realp), generalized matrix (genmat), or tunable gain surface (tunableSurface), then C2 is a generalized state-space model (genss).

Properties

expand all

PID controller coefficients, specified as scalars. When creating a pid2 controller object or array of objects, specify these coefficients in the Kp, Ki, Kd, Tf, b, and c input arguments.

Discrete integrator formula IF(z) for the integrator of the discrete-time pid2 controller:

u=Kp(bry)+KiIF(z)(ry)+KdTf+DF(z)(cry)

Specify IFormula as one of the following:

  • 'ForwardEuler'IF(z) = Tsz1.

    This formula is best for small sample time, where the Nyquist limit is large compared to the bandwidth of the controller. For larger sample time, the ForwardEuler formula can result in instability, even when discretizing a system that is stable in continuous time.

  • 'BackwardEuler'IF(z) = Tszz1.

    An advantage of the BackwardEuler formula is that discretizing a stable continuous-time system using this formula always yields a stable discrete-time result.

  • 'Trapezoidal'IF(z) = Ts2z+1z1.

    An advantage of the Trapezoidal formula is that discretizing a stable continuous-time system using this formula always yields a stable discrete-time result. Of all available integration formulas, the Trapezoidal formula yields the closest match between frequency-domain properties of the discretized system and the corresponding continuous-time system.

When C2 is a continuous-time controller, IFormula is ''.

Discrete integrator formula DF(z) for the derivative filter of the discrete-time pid2 controller:

u=Kp(bry)+KiIF(z)(ry)+KdTf+DF(z)(cry)

Specify DFormula as one of the following:

  • 'ForwardEuler'DF(z) = Tsz1.

    This formula is best for small sample time, where the Nyquist limit is large compared to the bandwidth of the controller. For larger sample time, the ForwardEuler formula can result in instability, even when discretizing a system that is stable in continuous time.

  • 'BackwardEuler'DF(z) = Tszz1.

    An advantage of the BackwardEuler formula is that discretizing a stable continuous-time system using this formula always yields a stable discrete-time result.

  • 'Trapezoidal'DF(z) = Ts2z+1z1.

    An advantage of the Trapezoidal formula is that discretizing a stable continuous-time system using this formula always yields a stable discrete-time result. Of all available integration formulas, the Trapezoidal formula yields the closest match between frequency-domain properties of the discretized system and the corresponding continuous-time system.

The Trapezoidal value for DFormula is not available for a pid2 controller with no derivative filter (Tf = 0).

When C2 is a continuous-time controller, DFormula is ''.

This property is read-only.

Time delay on the system input. InputDelay is always 0 for a pid2 controller object.

This property is read-only.

Time delay on the system output. OutputDelay is always 0 for a pid2 controller object.

Sample time, specified as:

  • 0 for continuous-time systems.

  • A positive scalar representing the sampling period of a discrete-time system. Ts in specified in the time unit specified by the TimeUnit property.

If pid2 is an array of PID controllers, the same Ts applies to all controllers.

Time variable units, specified as one of the following:

  • 'nanoseconds'

  • 'microseconds'

  • 'milliseconds'

  • 'seconds'

  • 'minutes'

  • 'hours'

  • 'days'

  • 'weeks'

  • 'months'

  • 'years'

Changing TimeUnit has no effect on other properties, but changes the overall system behavior. Use chgTimeUnit to convert between time units without modifying system behavior.

Input channel name, specified as a character vector or a 2-by-1 cell array of character vectors. Use this property to name the input channels of the controller model. For example, assign the names setpoint and measurement to the inputs of a 2-DOF PID controller model C as follows.

C.InputName = {'setpoint';'measurement'};

Alternatively, use automatic vector expansion to assign both input names. For example:

C.InputName = 'C-input';

The input names automatically expand to {'C-input(1)';'C-input(2)'}.

You can use the shorthand notation u to refer to the InputName property. For example, C.u is equivalent to C.InputName.

Input channel names have several uses, including:

  • Identifying channels on model display and plots

  • Specifying connection points when interconnecting models

Input channel units, specified as a 2-by-1 cell array of character vectors. Use this property to track input signal units. For example, assign the units Volts to the reference input and the concentration units mol/m^3 to the measurement input of a 2-DOF PID controller model C as follows.

C.InputUnit = {'Volts';'mol/m^3'};

InputUnit has no effect on system behavior.

Input channel groups. This property is not needed for PID controller models.

By default, InputGroup is a structure with no fields.

Output channel name, specified as one of the following:

  • A character vector.

  • '', no name specified.

For example, assign the name 'control' to the output of a controller model C as follows.

C.OutputName = 'control';

You can also use the shorthand notation y to refer to the OutputName property. For example, C.y is equivalent to C.OutputName.

Use OutputName to:

  • Identify channels on model display and plots.

  • Specify connection points when interconnecting models.

Output channel units, specified as one of the following:

  • A character vector.

  • '', no units specified.

Use OutputUnit to specify output signal units. OutputUnit has no effect on system behavior.

For example, assign the unit 'volts' to the output of a controller model C as follows.

C.OutputUnit = 'volts';

Output channel groups. This property is not needed for PID controller models.

By default, OutputGroup is a structure with no fields.

User-specified text that you want to associate with the system, specified as a character vector or cell array of character vectors. For example, 'System is MIMO'.

User-specified data that you want to associate with the system, specified as any MATLAB data type.

System name, specified as a character vector. For example, 'system_1'.

Sampling grid for model arrays, specified as a structure array.

Use SamplingGrid to track the variable values associated with each model in a model array, including identified linear time-invariant (IDLTI) model arrays.

Set the field names of the structure to the names of the sampling variables. Set the field values to the sampled variable values associated with each model in the array. All sampling variables must be numeric scalars, and all arrays of sampled values must match the dimensions of the model array.

For example, you can create an 11-by-1 array of linear models, sysarr, by taking snapshots of a linear time-varying system at times t = 0:10. The following code stores the time samples with the linear models.

 sysarr.SamplingGrid = struct('time',0:10)

Similarly, you can create a 6-by-9 model array, M, by independently sampling two variables, zeta and w. The following code maps the (zeta,w) values to M.

[zeta,w] = ndgrid(<6 values of zeta>,<9 values of w>)
M.SamplingGrid = struct('zeta',zeta,'w',w)

When you display M, each entry in the array includes the corresponding zeta and w values.

M
M(:,:,1,1) [zeta=0.3, w=5] =
 
        25
  --------------
  s^2 + 3 s + 25
 

M(:,:,2,1) [zeta=0.35, w=5] =
 
         25
  ----------------
  s^2 + 3.5 s + 25
 
...

For model arrays generated by linearizing a Simulink® model at multiple parameter values or operating points, the software populates SamplingGrid automatically with the variable values that correspond to each entry in the array. For instance, the Simulink Control Design™ commands linearize (Simulink Control Design) and slLinearizer (Simulink Control Design) populate SamplingGrid automatically.

By default, SamplingGrid is a structure with no fields.

Object Functions

The following lists contain a representative subset of the functions you can use with pid2 models. In general, any function applicable to Dynamic System Models is applicable to a pid2 object.

expand all

stepStep response of dynamic system
impulseImpulse response plot of dynamic system; impulse response data
lsimCompute time response simulation data of dynamic system to arbitrary inputs
bodeBode frequency response of dynamic system
nyquistNyquist response of dynamic system
nicholsNichols response of dynamic system
bandwidthFrequency response bandwidth
polePoles of dynamic system
zeroZeros and gain of SISO dynamic system
pzplotPlot pole-zero map of dynamic system
marginGain margin, phase margin, and crossover frequencies
zpkZero-pole-gain model
ssState-space model
c2dConvert model from continuous to discrete time
d2cConvert model from discrete to continuous time
d2dResample discrete-time model
feedbackFeedback connection of multiple models
connectBlock diagram interconnections of dynamic systems
seriesSeries connection of two models
parallelParallel connection of two models
pidtunePID tuning algorithm for linear plant model
rlocusRoot locus of dynamic system
piddataAccess coefficients of parallel-form PID controller
make2DOFConvert 1-DOF PID controller to 2-DOF controller
pidTunerOpen PID Tuner for PID tuning
tunablePIDTunable PID controller

Examples

collapse all

Create a continuous-time 2-DOF controller with proportional and derivative gains and a filter on the derivative term. To do so, set the integral gain to zero. Set the other gains and the filter time constant to the desired values.

Kp = 1;
Ki = 0;   % No integrator
Kd = 3;
Tf = 0.1;
b = 0.5;    % setpoint weight on proportional term
c = 0.5;    % setpoint weight on derivative term
C2 = pid2(Kp,Ki,Kd,Tf,b,c)
C2 =
 
                         s    
  u = Kp (b*r-y) + Kd -------- (c*r-y)
                       Tf*s+1 

  with Kp = 1, Kd = 3, Tf = 0.1, b = 0.5, c = 0.5
 
Continuous-time 2-DOF PDF controller in parallel form.

The display shows the controller type, formula, and parameter values, and verifies that the controller has no integrator term.

Create a discrete-time 2-DOF PI controller using the trapezoidal discretization formula. Specify the formula using Name,Value syntax.

Kp = 5;
Ki = 2.4;
Kd = 0;    
Tf = 0; 
b = 0.5;   
c = 0;      
Ts = 0.1;
C2 = pid2(Kp,Ki,Kd,Tf,b,c,Ts,'IFormula','Trapezoidal')
C2 =
 
                      Ts*(z+1)
  u = Kp (b*r-y) + Ki -------- (r-y)
                      2*(z-1) 

  with Kp = 5, Ki = 2.4, b = 0.5, Ts = 0.1
 
Sample time: 0.1 seconds
Discrete-time 2-DOF PI controller in parallel form.

Setting Kd = 0 specifies a PI controller with no derivative term. As the display shows, the values of Tf and c are not used in this controller. The display also shows that the trapezoidal formula is used for the integrator.

Create a 2-DOF PID controller, and set the dynamic system properties InputName and OutputName. Naming the inputs and the output is useful, for example, when you interconnect the PID controller with other dynamic system models using the connect command.

C2 = pid2(1,2,3,0,1,1,'InputName',{'r','y'},'OutputName','u')
C2 =
 
                       1              
  u = Kp (b*r-y) + Ki --- (r-y) + Kd*s (c*r-y)
                       s              

  with Kp = 1, Ki = 2, Kd = 3, b = 1, c = 1
 
Continuous-time 2-DOF PID controller in parallel form.

A 2-DOF PID controller has two inputs and one output. Therefore, the 'InputName' property is an array containing two names, one for each input. The model display does not show the input and output names for the PID controller, but you can examine the property values to see them. For instance, verify the input name of the controller.

C2.InputName
ans = 2x1 cell
    {'r'}
    {'y'}

Create a 2-by-3 grid of 2-DOF PI controllers with proportional gain ranging from 1–2 across the array rows and integral gain ranging from 5–9 across columns.

To build the array of PID controllers, start with arrays representing the gains.

Kp = [1 1 1;2 2 2];
Ki = [5:2:9;5:2:9];

When you pass these arrays to the pid2 command, the command returns the array of controllers.

pi_array = pid2(Kp,Ki,0,0,0.5,0,'Ts',0.1,'IFormula','BackwardEuler');
size(pi_array)
2x3 array of 2-DOF PID controller.
Each PID has 1 output and 2 inputs.

If you provide scalar values for some coefficients, pid2 automatically expands them and assigns the same value to all entries in the array. For instance, in this example, Kd = Tf = 0, so that all entries in the array are PI controllers. Also, all entries in the array have b = 0.5.

Access entries in the array using array indexing. For dynamic system arrays, the first two dimensions are the I/O dimensions of the model, and the remaining dimensions are the array dimensions. Therefore, the following command extracts the (2,3) entry in the array.

pi23 = pi_array(:,:,2,3)
pi23 =
 
                       Ts*z 
  u = Kp (b*r-y) + Ki ------ (r-y)
                        z-1 

  with Kp = 2, Ki = 9, b = 0.5, Ts = 0.1
 
Sample time: 0.1 seconds
Discrete-time 2-DOF PI controller in parallel form.

You can also build an array of PID controllers using the stack command.

C2 = pid2(1,5,0.1,0,0.5,0.5);         % PID controller
C2f = pid2(1,5,0.1,0.5,0.5,0.5);      % PID controller with filter
pid_array = stack(2,C2,C2f);          % stack along 2nd array dimension

These commands return a 1-by-2 array of controllers.

size(pid_array)
1x2 array of 2-DOF PID controller.
Each PID has 1 output and 2 inputs.

All PID controllers in an array must have the same sample time, discrete integrator formulas, and dynamic system properties such as InputName and OutputName.

Convert a standard-form pidstd2 controller to parallel form.

Standard PID form expresses the controller actions in terms of an overall proportional gain Kp, integrator and derivative time constants Ti and Td, and filter divisor N. You can convert any 2-DOF standard-form controller to parallel form using the pid2 command. For example, consider the following standard-form controller.

Kp = 2;
Ti = 3;
Td = 4;
N = 50;
b = 0.1;
c = 0.5;
C2_std = pidstd2(Kp,Ti,Td,N,b,c)
C2_std =
 
                       1      1                      s      
  u = Kp * [(b*r-y) + ---- * --- * (r-y) + Td * ------------ * (c*r-y)]
                       Ti     s                  (Td/N)*s+1 

  with Kp = 2, Ti = 3, Td = 4, N = 50, b = 0.1, c = 0.5
 
Continuous-time 2-DOF PIDF controller in standard form

Convert this controller to parallel form using pid2.

C2_par = pid2(C2_std)
C2_par =
 
                       1                s    
  u = Kp (b*r-y) + Ki --- (r-y) + Kd -------- (c*r-y)
                       s              Tf*s+1 

  with Kp = 2, Ki = 0.667, Kd = 8, Tf = 0.08, b = 0.1, c = 0.5
 
Continuous-time 2-DOF PIDF controller in parallel form.

A response plot confirms that the two forms are equivalent.

bodeplot(C2_par,'b-',C2_std,'r--')
legend('Parallel','Standard','Location','Southeast')

MATLAB figure

ans = 
  Legend (Parallel, Standard) with properties:

         String: {'Parallel'  'Standard'}
       Location: 'southeast'
    Orientation: 'vertical'
       FontSize: 8.1000
       Position: [0.7651 0.5782 0.2123 0.0884]
          Units: 'normalized'

  Use GET to show all properties

Convert a discrete-time dynamic system that represents a 2-DOF PID controller with derivative filter to parallel pid2 form.

The following state-space matrices represent a discrete-time 2-DOF PID controller with a sample time of 0.1 s.

A = [1,0;0,0.99];
B = [0.1,-0.1; -0.005,0.01];
C = [3,0.2];
D = [2.6,-5.2];
Ts = 0.1;
sys = ss(A,B,C,D,Ts);

When you convert sys to 2-DOF PID form, the result depends on which discrete integrator formulas you specify for the conversion. For instance, use the default, ForwardEuler, for both the integrator and the derivative.

C2fe = pid2(sys)
C2fe =
 
                        Ts                   1     
  u = Kp (b*r-y) + Ki ------ (r-y) + Kd ----------- (c*r-y)
                        z-1             Tf+Ts/(z-1)

  with Kp = 5, Ki = 3, Kd = 2, Tf = 10, b = 0.5, c = 0.5, Ts = 0.1
 
Sample time: 0.1 seconds
Discrete-time 2-DOF PIDF controller in parallel form.

Now convert using the Trapezoidal formula.

C2trap = pid2(sys,'IFormula','Trapezoidal','DFormula','Trapezoidal')
C2trap =
 
                      Ts*(z+1)                     1         
  u = Kp (b*r-y) + Ki -------- (r-y) + Kd ------------------- (c*r-y)
                      2*(z-1)             Tf+Ts/2*(z+1)/(z-1)

  with Kp = 4.85, Ki = 3, Kd = 2, Tf = 9.95, b = 0.485, c = 0.5, Ts = 0.1
 
Sample time: 0.1 seconds
Discrete-time 2-DOF PIDF controller in parallel form.

The displays show the difference in resulting coefficient values and functional form.

Discretize a continuous-time 2-DOF PID controller and specify the integral and derivative filter formulas.

Create a continuous-time controller and discretize it using the zero-order-hold method of the c2d command.

C2con = pid2(10,5,3,0.5,1,1);  % continuous-time 2-DOF PIDF controller
C2dis1 = c2d(C2con,0.1,'zoh')
C2dis1 =
 
                        Ts                   1     
  u = Kp (b*r-y) + Ki ------ (r-y) + Kd ----------- (c*r-y)
                        z-1             Tf+Ts/(z-1)

  with Kp = 10, Ki = 5, Kd = 3.31, Tf = 0.552, b = 1, c = 1, Ts = 0.1
 
Sample time: 0.1 seconds
Discrete-time 2-DOF PIDF controller in parallel form.

The display shows that c2d computes new PID coefficients for the discrete-time controller.

The discrete integrator formulas of the discretized controller depend on the c2d discretization method, as described in Tips. For the zoh method, both IFormula and DFormula are ForwardEuler.

C2dis1.IFormula
ans = 
'ForwardEuler'
C2dis1.DFormula
ans = 
'ForwardEuler'

If you want to use different formulas from the ones returned by c2d, then you can directly set the Ts, IFormula, and DFormula properties of the controller to the desired values.

C2dis2 = C2con;
C2dis2.Ts = 0.1; 
C2dis2.IFormula = 'BackwardEuler';
C2dis2.DFormula = 'BackwardEuler';

However, these commands do not compute new PID gains for the discretized controller. To see this, examine C2dis2 and compare the coefficients to C2con and C2dis1.

C2dis2
C2dis2 =
 
                       Ts*z                   1      
  u = Kp (b*r-y) + Ki ------ (r-y) + Kd ------------- (c*r-y)
                        z-1             Tf+Ts*z/(z-1)

  with Kp = 10, Ki = 5, Kd = 3, Tf = 0.5, b = 1, c = 1, Ts = 0.1
 
Sample time: 0.1 seconds
Discrete-time 2-DOF PIDF controller in parallel form.

Tips

  • To break a 2-DOF controller into two SISO control components, such as a feedback controller and a feedforward controller, use getComponents.

  • Create arrays of pid2 controller objects by:

    • Specifying array values for one or more of the coefficients Kp, Ki, Kd, Tf, b, and c.

    • Specifying an array of dynamic systems sys to convert to pid2 controller objects.

    • Using stack to build arrays from individual controllers or smaller arrays.

    • Passing an array of plant models to pidtune.

    In an array of pid2 controllers, each controller must have the same sample time Ts and discrete integrator formulas IFormula and DFormula.

  • To create or convert to a standard-form controller, use pidstd2. Standard form expresses the controller actions in terms of an overall proportional gain Kp, integral and derivative times Ti and Td, and filter divisor N. For example, the relationship between the inputs and output of a continuous-time standard-form 2-DOF PID controller is given by:

    u=Kp[(bry)+1Tis(ry)+TdsTdNs+1(cry)]

  • There are two ways to discretize a continuous-time pid2 controller:

    • Use the c2d command. c2d computes new parameter values for the discretized controller. The discrete integrator formulas of the discretized controller depend upon the c2d discretization method you use, as shown in the following table.

      c2d Discretization MethodIFormulaDFormula
      'zoh'ForwardEulerForwardEuler
      'foh'TrapezoidalTrapezoidal
      'tustin'TrapezoidalTrapezoidal
      'impulse'ForwardEulerForwardEuler
      'matched'ForwardEulerForwardEuler

      For more information about c2d discretization methods, See the c2d reference page. For more information about IFormula and DFormula, see Properties.

    • If you require different discrete integrator formulas, you can discretize the controller by directly setting Ts, IFormula, and DFormula to the desired values. (See Discretize a Continuous-Time 2-DOF PID Controller.) However, this method does not compute new gain and filter-constant values for the discretized controller. Therefore, this method might yield a poorer match between the continuous- and discrete-time pid2 controllers than using c2d.

Version History

Introduced in R2015b