Hello,
I want to set the Floating Point IP Library to the XILINX IP Logicore, but I get the following error from the Configuration Parameters of Simulink: "Unable to find the software for XILINXLOGICORE. Make Sure it is installed with Xilinx ISE and use hdlsetuptoolpath to set up Xilinx ISE."
My configuration:
  • Windows 10 64-bits
  • Matlab 2019b
  • Xilinx Vivado 2019.2 with System Generator 2019.2
I already setup the path with the following command:
hdlsetuptoolpath('ToolName', 'Xilinx Vivado', 'ToolPath', 'D:\Xilinx\Vivado\2019.2\bin');
The command !vivado executes Vivado 2019.2.
>> ver
-----------------------------------------------------------------------------------------------------
MATLAB Version: 9.7.0.1247435 (R2019b) Update 2
MATLAB License Number: 976913
Operating System: Microsoft Windows 10 Professionnel Version 10.0 (Build 16299)
Java Version: Java 1.8.0_202-b08 with Oracle Corporation Java HotSpot(TM) 64-Bit Server VM mixed mode
-----------------------------------------------------------------------------------------------------
MATLAB Version 9.7 (R2019b)
Simulink Version 10.0 (R2019b)
Fixed-Point Designer Version 6.4 (R2019b)
HDL Coder Version 3.15 (R2019b)
MATLAB Coder Version 4.3 (R2019b)
Simscape Version 4.7 (R2019b)
Simscape Electrical Version 7.2 (R2019b)
Simulink Coder Version 9.2 (R2019b)
Could you please tell me how to set the Floating Point IP Library to the XILINX IP Logicore ?

Accepted Answer

Kiran Kintali
Kiran Kintali on 6 Jan 2020
Edited: Stefanie Schwarz on 4 Mar 2024
It is possible Xilinx LOGICORE is not avaialble with Vivado and you need to setup Xilinx ISE to use it. Please check Xilinx Documentation.
Per HDL Coder documentation Xilinx Vivado is not supported for target floating point code generation. Please consider using Native Floating Point code generation option as a work around.
  3 Comments
Jonathan Howard
Jonathan Howard on 25 Feb 2020
And ISE doesn't support a lot of the newer devices, so why does HDL Coder still rely on it?
Kiran Kintali
Kiran Kintali on 25 Feb 2020
HDLCoder does not rely on Xilinx ISE. If a user has installed the ISE software it continues to support the workflow with these tools as much as possible.

Sign in to comment.

More Answers (1)

Kiran Kintali
Kiran Kintali on 6 Jan 2020
hi Samuel,
hsetup_vivado.PNG
There is a special Note about Vivado in the help text:
Please note that Xilinx Vivado launcher for Windows is a '.bat' file. If you are providing full path to the launcher to hdlsetuptoolpath, make sure to provide correct '.bat' file.
Thanks