How can I change the active variant subsystem before simulation starts?
6 views (last 30 days)
Show older comments
I have a model with multiple instances of a variant subsystem. The variant subsystem itself is in a library. How can I choose which variant to use for each instance using a script? Currently I use the PostLoadFcn callback of my top model to set active variant of each instance using set_param(). But if I edit the variant library block (and I do this often), all instances go back to the default variant in my top model. So I need a way to change them back before I run a simulation, and I don't want to have to close and re-open the top model just to do this (invoking the PostLoadFcn callback).
If I use the InitFcn to set the active variant, I get an error that I can't change variant during simulation.
0 Comments
Answers (1)
Ankit Bhardwaj
on 26 Apr 2017
Edited: Ankit Bhardwaj
on 26 Apr 2017
There can be multiple ways to solve this issue.
1. Create an empty subsystem at the top level with an openFcn callback with the same code which you have in postLoadFcn callback. This will be able to fix the variants in one click.
2. You can also think of using Variant objects in the base workspace to fix this issue.
See Also
Categories
Find more on Component-Based Modeling in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!