Loss of access to the reference sub system location caused all the connections to become 'disconnected' even though the lines remained intact. Deleting and reinserting each trigger signal resolved the warnings
Unclear error message for Swicth-Case Action on model update
4 views (last 30 days)
Show older comments
Graham Cotgreave
on 24 Aug 2022
Answered: Graham Cotgreave
on 24 Aug 2022
The error message "The action port on subsystem '......../Chip1_WriteBytes1' can only be connected to an If or Switch-Case and may not be connected to more than one If or Switch-Case" is raised whe updating the model with the following diagram.
It would appear that each of the individual cases is only connected to one action port in one subsystem, so the reason for the error message is unclear.
Can anyone shed light on the reason this error is being raised.
0 Comments
Accepted Answer
More Answers (0)
See Also
Categories
Find more on Event Functions in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!