Main Content

Specify Parameters Requirements

In the Sensitivity Analyzer, you can specify the following constraints on Simulink® model parameters that are specified as variables:

For information about how to specify a model parameter as a variable, see Add Model Parameters as Variables.

Impose Monotonic Constraint Requirement on Variable

You can impose a monotonic constraint requirement on a variable in your Simulink model. For example, constrain a variable to be monotonically increasing. The variable can be a vector, matrix, or multidimensional array that is a parameter in your model, such as the breakpoints of a lookup table.

To specify the requirement:

  1. In the Sensitivity Analyzer, in the New Requirement drop-down list, select Monotonic Variable.

    New Requirement icon is highlighted on the Sensitivity Analysis toolstrip in the app

    In the Create Requirement dialog box, specify the requirement. A new requirement with the name specified in Name appears in the Requirements area of the app.

    Create Requirement dialog box

  2. Specify the name of the variable in Variable. The variable must be a vector, matrix, or multidimensional array of data type double or single.

    You can type the name of a nonscalar variable, or select the variable from the drop-down list. The list is prepopulated with all the nonscalar variables in your model. To choose a subset of an array or matrix variable V, type an expression. For example, specify Variable as V(1,:) to use the first row of the variable. To use a numeric nonscalar field x of a structure S, type S.x. You cannot use mathematical expressions such as a + b.

    Sometimes, models have parameters that are not explicitly defined in the model itself. For example, a gain k could be defined in the MATLAB®  workspace as k = a + b, where a and b are not defined in the model but k is used. To add these independent parameters as variables in the app, see Add Model Parameters as Variables.

  1. Specify the monotonicity for each dimension of the variable.

    After you select the variable, the dialog box updates to show Dimension 1 to Dimension n, corresponding to the n dimensions of the variable. For example, for a 2-dimensional variable K of size 3-by-5, the dialog box updates as shown.

    Specify monotonic constraint section with Variable as K2, Dimension 1 as Strictly increasing and Dimension 2 as Strictly decreasing in the Create Requirement dialog box

    Specify the monotonicity for the first dimension in Dimension 1 and for the nth-dimension in Dimension n as one of the following options:

    • Strictly increasing — Each element of the variable is greater than the previous element in that dimension.

    • Increasing — Each element of the variable is greater than or equal to the previous element in that dimension.

    • Decreasing — Each element of the variable is less than or equal to the previous element in that dimension.

    • Strictly decreasing — Each element of the variable is less than the previous element in that dimension.

    • Not constrained — No constraint exists between the elements of the variable in that dimension.

  1. Close the Create Requirement dialog box.

    The requirement created in the Requirements area of the app is updated with the specified characteristics.

You can now evaluate the requirement. For more information, see Evaluate Design Requirements. When you perform evaluation, the app returns the evaluated requirement value corresponding to each dimension of the variable. A positive requirement value indicates that the requirement has been violated.

Impose Upper Bound on Gradient Magnitude of Variable

You can impose an upper bound on the gradient magnitude of a variable in your Simulink model. The variable can be a vector, matrix, or multidimensional array that is a parameter in your model, such as the data of a lookup table. For example, consider a car engine controller whose gain changes under different operating conditions determined by the car speed. You can use a gradient bound constraint to limit the rate at which the controller gain changes per unit change in vehicle speed.

For an N-dimensional variable F that is a function of independent variables x1,..., xN, the gradient magnitude is defined as:

|F|=(Fx1)2+(Fx2)2++(FxN)2

To compute the gradient magnitude, the software computes the partial derivative in each dimension by computing the difference between successive F data in that dimension and dividing by the spacing between the data in that dimension. You specify F and the spacing between the data. The software checks whether the gradient magnitude of the variable data is less than or equal to a specified bound. If the gradient magnitude of the data is greater than the required bound, the variable data is not smooth.

To specify the requirement:

  1. In the Sensitivity Analyzer, in the New Requirement drop-down list, select Smoothness Constraint.

    New Requirement icon is highlighted on the Sensitivity Analysis toolstrip in the app

    In the Create Requirement dialog box, specify the requirement. A new requirement with the name specified in Name appears in the Requirements area of the app.

    Create Requirement dialog box

  2. Specify the gradient magnitude bound as a nonnegative finite real scalar in Gradient maximum magnitude.

  3. Specify the variable F that you want to impose the requirement on in Dependent Variable. The variable must be a vector, matrix, or multidimensional array of data type double or single. The variable must be a parameter in your model or a constant that you enter.

    You can type the name of a nonscalar variable or a constant, or select the variable from the drop-down list. The list is prepopulated with all the nonscalar variables in your model. To choose a subset of an array or matrix variable V, type an expression. For example, specify Variable as V(1,:) to use the first row of the variable. To use a numeric nonscalar field x of a structure S, type S.x. You cannot use mathematical expressions such as a + b.

    Sometimes, models have parameters that are not explicitly defined in the model itself. For example, a gain k could be defined in the MATLAB  workspace as k = a + b, where a and b are not defined in the model but k is used. To add these independent parameters as variables in the app, see Add Model Parameters as Variables.

  1. Specify the spacing between points of Dependent Variable data in each dimension in Independent Variable.

    After you select the Dependent Variable, the dialog box updates to show Dimension 1 to Dimension n, corresponding to the n dimensions of the dependent variable. For example, for a 1-dimensional variable K, the dialog box updates as shown.

    Specify smoothness constraint section with Gradient maximum magnitude as 1, Dependent variable as K and Dimension 1 of independent variable to be selected from drop-down

    The first dimension specifies the spacing going down the dependent variable data rows, and the second specifies spacing across the columns. The Nth dimension specifies the spacing along the Nth dimension of dependent variable data. You can specify the independent variables in each dimension as scalars or vectors.

    • Scalars — Specify the spacing between dependent variable data F in the corresponding dimension as a nonzero scalar. For example, suppose that Dependent Variable is two-dimensional, and the spacing between data in the first dimension is 5 and in the second dimension is 2. In the Independent Variable section, specify Dimension 1 as 5 and Dimension 2 as 2.

    • Vectors — Specify the coordinates of F data in the corresponding dimension as real, numeric, monotonic vectors. The software uses the coordinates to compute the spacing between the dependent variable data points in the corresponding dimension. The length of the vector must match the length of F in the corresponding dimension. You do not have to specify coordinates with uniform spacing. For example, suppose that F is two-dimensional, and the length of the data in the first and second dimension is 3 and 5, respectively. The coordinates of the data in the first dimension are [1 2 3]. In the second dimension, the spacing is not uniform and the coordinates of the data are [1 2 10 20 30]. In the Independent Variable section, specify Dimension 1 as [1 2 3] and Dimension 2 as [1 2 10 20 30].

    You can also specify the independent variables by typing the name of a variable, or selecting a variable from the drop-down list. The list is prepopulated with all the variables in your model that have the appropriate size. To choose a subset of an array or matrix variable V, type an expression. For example, specify as V(1,:) to use the first row of the variable. To use a numeric field x of a structure S, type S.x. You cannot use mathematical expressions such as a + b.

  1. Close the Create Requirement dialog box.

    The requirement created in the Requirements area of the app is updated with the specified characteristics.

You can now evaluate the requirement. For more information, see Evaluate Design Requirements. When you perform evaluation, the app returns the evaluated requirement value. A positive requirement value indicates that the requirement has been violated.

Specify Linear or Quadratic Function Matching Constraint

In the app, you can constrain a variable's values to match a linear or quadratic function. The variable can be a vector, matrix, or a multidimensional array that is a parameter in your model, such as the data of a lookup table in your model. To specify the requirement:

  1. In Sensitivity Analyzer, from the New Requirement drop-down list, select Function Matching.

    New Requirement icon is highlighted on the Sensitivity Analysis toolstrip in the app

    In the Create Requirement dialog box, specify the requirement. A new requirement with the name specified in Name appears in the Requirements area of the app.

    Create Requirement dialog box

  2. Specify the function to be matched. To do so, set Functional Relation to one of the following values:

    • Linear — Data from variable V are fit to a linear function. For example, for a two-dimensional variable with independent variables, X1 and X2, the linear function has the form:

      V=a0+a1X1+a2X2

      The software calculates the fit coefficients a0, a1, and a2 and then calculates the sum of squares of the error between the data and the linear function.

    • Quadratic with no cross-terms — Data are fit to a quadratic function with no cross-terms. For a two-dimensional variable, the pure quadratic function has the form:

      V=a0+a1X1+a2X12+a3X2+a4X22

    • Quadratic with all cross-terms — Variable data are fit to a quadratic function that includes cross-terms. For a two-dimensional variable, the quadratic function has the form:

      V=a0+a1X1+a2X12+a3X2+a4X22+a5X1X2

      If the variable is one-dimensional, there are no cross-terms and so the computation is the same as when Functional relation is Quadratic with no cross-terms.

  3. Specify the variable V to which you want to apply the requirement in Dependent Variable. The variable must be a vector, matrix, or multidimensional array of data type double or single that is a parameter in your model.

    Type the name of a non scalar variable, or select a variable from the drop-down list. The list is prepopulated with all the nonscalar variables in your model. To see where the selected variable is used on your model, click Show in Model. To choose a subset of an array or matrix variable A, type an expression. For example, specify A(1,:) to use the first row of the variable. To use a numeric nonscalar field x of a structure S, type S.x. You cannot use mathematical expressions such as a + b.

    Sometimes models have parameters that are not explicitly defined in the model itself. For example, a gain k could be defined in the MATLAB workspace as k = a + b, where a and b are not defined in the model but k is used. To add these independent parameters as design variables in the app, see Add Model Parameters as Variables.

  4. Specify the independent variable vectors used for computing the function in Independent Variable. The independent variables are specified as real, numeric, monotonic vectors.

    The number of independent variables must equal the number of dimensions of the dependent variable V. For example, you specify two independent variables when V is a matrix, and use three independent variables when V is three-dimensional. The first independent variable vector specifies coordinates going down the rows of V, and the second independent variable vector specifies coordinates going across the columns of V. The nth independent variable vector specifies coordinates along the nth dimension of V. The number of elements in each independent variable vector must match the size of V in the corresponding dimension. The independent variable vectors must be monotonically increasing or decreasing.

    You can also specify the independent variables by typing the name of a variable, or selecting a variable from the drop-down list. The list is prepopulated with all the variables in your model that have the appropriate size. To choose a subset of an array or matrix variable A, type an expression. For example, specify A(1,:) to use the first row of the variable. To use a numeric field x of a structure S, type S.x. You cannot use mathematical expressions such as a + b. To use an equally spaced vector, select [1 2 ...N] from the drop-down menu.

  5. Specify whether you want to center and scale the independent variables. When you select the Center and scale independent variables option, the independent variable vectors you specify are divided by a scale value after subtracting a center value. Centering can improve numerical conditioning when one or more independent variable vectors have a mean that differs from 0 by several orders of magnitude. Scaling can improve numerical conditioning when independent variable vectors differ from each other by several orders of magnitude.

    To specify the center and scale values for each independent variable, expand the Center and Scale Settings section, and select one of the following:

    • Use automatic centers and scales - The center and scale values are the mean and standard deviation for each independent variable. Using the mean and standard deviation values to center and scale the independent variables is the default option.

    • Use custom centers and scales - Specify the Center and Scale values for each independent variable. The independent variable vectors are divided by the corresponding Scale value after subtracting the value you specify in Center.

  6. Close the Create Requirement dialog box.

    The requirement created in the Requirements area of the app is updated with the specified characteristics.

You can now evaluate the requirement. For more information, see Evaluate Design Requirements. When you perform evaluation, the app returns the evaluated requirement value. The app computes an error signal that is the difference between the dependent variable data and the specified function of the independent variables. The app returns the sum of squares of this error as the evaluated requirement value. A positive value indicates that the requirement has been violated, and 0 value indicates that the requirement is satisfied. The closer the value is to 0, the better is the match between the function and dependent variable data.

Specify Requirement on a Vector Property

In the app, you can specify a requirement on a vector property, such as the mean value of the vector. The vector must be a parameter in your model. To specify the requirement:

  1. In the Sensitivity Analyzer, in the New Requirement drop-down list, select Vector Property.

    New Requirement icon is highlighted on the Sensitivity Analysis toolstrip in the app

    In the Create Requirement dialog box, specify the requirement. A new requirement with the name specified in Name appears in the Requirements area of the app.

    Create Requirement dialog box

  1. Specify the vector property in Property. For a vector V with N elements, you can specify one of the following properties:

    • Vector meanmean(V)

    • Vector medianmedian(V)

    • Vector variancevariance(V)

    • Vector inter-quartile range — Difference between the 75th and 25th percentiles of the vector values.

    • Vector sumi=1NV(i)

    • Vector sum of squaresi=1NV(i)2

    • Vector sum of absolute valuesi=1N|V(i)|

    • Vector minimummin(V)

    • Vector maximummax(V)

  2. Specify the type of requirement you want to impose on the vector property in Type. You can set an upper or lower bound on the vector property, or require the property to equal a particular value. You can also choose to maximize or minimize the vector property. For example, to maximize the mean value of your vector, specify Property as Vector mean and Type as Maximize the property.

  3. Specify the value of the bound imposed on the vector property in Bound. Specify the bound as a finite real scalar value. For example, if for a vector variable V you require mean(V) = 5, specify Property as Vector mean, Type as Constrain property to be == the bound, and Bound as 5.

  1. Specify the name of the variable in Variable. The variable must be a vector, matrix, or multidimensional array of data type double or single.

    You can type the name of a nonscalar variable, or select the variable from the drop-down list. The list is prepopulated with all the nonscalar variables in your model. To choose a subset of an array or matrix variable V, type an expression. For example, specify Variable as V(1,:) to use the first row of the variable. To use a numeric nonscalar field x of a structure S, type S.x. You cannot use mathematical expressions such as a + b.

    Sometimes, models have parameters that are not explicitly defined in the model itself. For example, a gain k could be defined in the MATLAB  workspace as k = a + b, where a and b are not defined in the model but k is used. To add these independent parameters as variables in the app, see Add Model Parameters as Variables.

  2. Close the Create Requirement dialog box.

    The requirement created in the Requirements area of the app is updated with the specified characteristics.

You can now evaluate the requirement. For more information, see Evaluate Design Requirements. When you perform evaluation, the app returns the evaluated requirement value. A positive requirement value indicates that the requirement has been violated.

Impose Relational Constraint Between Two Variables

You can impose a relational constraint requirement on a pair of variables in your Simulink model. For example, require that variable a is always greater than variable b. To specify the requirement:

  1. In the Sensitivity Analyzer, in the New Requirement drop-down list, select Relational Constraint.

    New Requirement icon is highlighted on the Sensitivity Analysis toolstrip in the app

    In the Create Requirement dialog box, specify the requirement. A new requirement with the name specified in Name appears in the Requirements area of the app.

    Create Requirement dialog box

  2. Specify the name of the two variables in Variable. The variables can be vectors or arrays but must be the same size.

    Type the name of two variables, or select the variables from the drop-down lists. The lists are prepopulated with all the variables in your model. To see where a selected variable is used on your model, click Show in Model. To choose a subset of an array or matrix variable V, type an expression. For example, specify Variable as V(1,:) to use the first row of the variable. To use a numeric field x of a structure S, type S.x. You cannot use mathematical expressions such as a + b.

    Sometimes, models have parameters that are not explicitly defined in the model itself. For example, a gain k could be defined in the MATLAB  workspace as k = a + b, where a and b are not defined in the model but k is used. To add these independent parameters as variables in the app, see Add Model Parameters as Variables.

  1. Specify the relation between the elements of the two variables as one of the following in Relationship:

    • '<' — Each data element in the first variable is less than the corresponding element in the second variable.

    • '<=' — Each data element in the first variable is less than or equal to the corresponding element in the second variable.

    • '>' — Each data element in the first variable is greater than the corresponding element in the second variable.

    • '>=' — Each data element in the first variable is greater than or equal to the corresponding element in the second variable.

    • '==' — Each data element in the first variable is equal to the corresponding element in the second variable.

    • '~=' — Each data element in the first variable is not equal to the corresponding element in the second variable.

  1. Close the Create Requirement dialog box.

    The requirement created in the Requirements area of the app is updated with the specified characteristics.

You can now evaluate the requirement. For more information, see Evaluate Design Requirements. When you perform evaluation, the app returns the evaluated requirement value. The interpretation of the evaluated requirement value depends on the requirement Type.

Type Evaluated Requirement Value
Requirement is SatisfiedRequirement is Violated
'>' or '<'Negative numberPositive number, or 0 if the elements are equal
'>=' or '<='Negative number, or 0 if the elements are equalPositive number
'=='0Non-zero number
'~='01

Related Topics