![photo](/responsive_image/150/150/0/0/0/cache/matlabcentral/profiles/6715533_1522117224425_DEF.jpg)
creepydog
Followers: 0 Following: 0
Statistics
RANK
7 781
of 297 016
REPUTATION
6
CONTRIBUTIONS
7 Questions
2 Answers
ANSWER ACCEPTANCE
42.86%
VOTES RECEIVED
6
RANK
of 20 419
REPUTATION
N/A
AVERAGE RATING
0.00
CONTRIBUTIONS
0 Files
DOWNLOADS
0
ALL TIME DOWNLOADS
0
CONTRIBUTIONS
0 Posts
CONTRIBUTIONS
0 Public Channels
AVERAGE RATING
CONTRIBUTIONS
0 Highlights
AVERAGE NO. OF LIKES
Feeds
Question
Power operator (^) precedence levels and evaluation order
While 2^-1^-2 returns 4, which indicates a "left to right" evaluation order (as it is common in many programming languages), ...
8 månader ago | 1 answer | 2
1
answerQuestion
Enabled Subsystem does not reliably disable
The Simulink model shown in the screenshot does not behave as I expect, and I would like to understand the reason. All blocks...
10 månader ago | 1 answer | 1
1
answerQuestion
Rank of symbolic matrix is wrong (but too small, not too large)
I get a wrong result using the sym/rank command. I'm aware of the limitations of this command as it does not simplify expression...
mer än 3 år ago | 1 answer | 1
1
answerQuestion
Simulation runs fine despite error (index out of bounds)
Hello. Summary For my simple model, Simulink (R2020b) throws an error during Model Update, but afterwards allows me to simulat...
ungefär 4 år ago | 1 answer | 1
1
answerNumber of necessary time steps to handle a Zero-Crossing?
First of all: Thank you for your efforts! Your guesses are similar to my guesses. ;-) I've been aware of the fact that my minim...
mer än 4 år ago | 0
Question
Number of necessary time steps to handle a Zero-Crossing?
Over the years I have observed that Simulink usually uses 3 time steps to handle a zero-crossing, but in some cases it uses only...
mer än 4 år ago | 2 answers | 0
2
answersWhat do TzL & TzR mean in Simulink Debugger ?
I've seen these when debugging zero-crossings. So "z" might mean "zero-crossing", "L" and "R" might be "left" (before) and "righ...
mer än 4 år ago | 0
Question
Integrator State Port: Why is its use restricted?
Hello. I'd like to know why the use of the Integrator Block's State Port is restricted (and I have some more questions, see bel...
mer än 4 år ago | 2 answers | 1
2
answersQuestion
How can I get the figure handle of a Scope window programmatically, given only the Scope block's full path name?
I've got the full path name of a Scope *block* as it is returned by find_system(...), e.g. 'myModel/Scope1'. In order to mani...
mer än 7 år ago | 2 answers | 0