Why does xPC Target 5.5 not recognise my PCI-PDISO8 Relay Card
It turns out that Measurement Computing (the card manufacturer) had performed an update to the card changing the register addres...
mer än 9 år ago | 0
| accepted
Question
Is it possible to send regular periodic messages using the Fastcomm 422/2-PCI-335
I have a setup where a target machine running xPC Target 5.5 is acting as a master on an RS-485 databus using the Fastcomm 422/2...
mer än 9 år ago | 0 answers | 0
0
answersQuestion
Is it possible to access the discrete input/output pins of the RCEI-530A ARINC 429 card?
I have an RCEI-530A ARINC429 card within my xpC Target 5.5 setup and I now have a need for a number of discrete outputs. I notic...
mer än 9 år ago | 0 answers | 0
0
answersQuestion
Is it possible to tune parameters in a model running standalone on a Raspberry Pi?
The question says it all really, but for more information I am a relatively experienced user of xPC target in a professional con...
nästan 10 år ago | 0 answers | 0
0
answersQuestion
Why does xPC Target 5.5 not recognise my PCI-PDISO8 Relay Card
I am using MatLab 2013b on a 64-bit host machine and xPC Target 5.5 with a setup that includes a Measurement Computing PCI-PDISO...
nästan 10 år ago | 1 answer | 0
1
answerQuestion
How do you interpret the output values of the status port of the NAII 76CL1 xPC Target Block in Simulink?
I am currently setting up a test rig which includes an xPC Target computer with an NAII 76CL1 VDT emulator card. I am having som...
nästan 10 år ago | 0 answers | 0
0
answersQuestion
Why can I not set the transformation ratio parameter to a non-integer value in the xPC NAII 76CL1 LVDT emulator card Simulink block
I am running a real-time model of an actuator using xPC Target and emulating the position of an LVDT which is connected to the a...
mer än 10 år ago | 1 answer | 0
1
answerQuestion
Is it possible log an undefined amount of data with an xPC Target File Scope?
In Simulink, a Scope or a To File block will log a data point at every time step (or at the specified sample time) from starting...
mer än 10 år ago | 1 answer | 0