photo

Alexandre


Last seen: ungefär ett år ago Active since 2012

Followers: 0   Following: 0

Message

Statistics

All
MATLAB Answers

10 Questions
4 Answers

Cody

0 Problems
1 Solution

RANK
26 139
of 300 381

REPUTATION
1

CONTRIBUTIONS
10 Questions
4 Answers

ANSWER ACCEPTANCE
60.0%

VOTES RECEIVED
1

RANK
 of 20 941

REPUTATION
N/A

AVERAGE RATING
0.00

CONTRIBUTIONS
0 Files

DOWNLOADS
0

ALL TIME DOWNLOADS
0

RANK
112 395
of 168 477

CONTRIBUTIONS
0 Problems
1 Solution

SCORE
20

NUMBER OF BADGES
1

CONTRIBUTIONS
0 Posts

CONTRIBUTIONS
0 Public Channels

AVERAGE RATING

CONTRIBUTIONS
0 Highlights

AVERAGE NO. OF LIKES

  • Solver
  • Thankful Level 3

View badges

Feeds

View by

Solved


Times 2 - START HERE
Try out this test problem first. Given the variable x as your input, multiply it by two and put the result in y. Examples:...

ungefär 8 år ago

Question


simulink output in a parfor loop
Hi all, I'm running a model and need to sweep through a lot of parameters so I am using the parallel computing toolbox. I usu...

mer än 10 år ago | 0 answers | 0

0

answers

Question


Pneumo-Hydraulic Actuator mechanical ports
I just discovered the Pneumo-Hydraulic Actuator which seems great for my application as I was previously using a gas accumulator...

mer än 10 år ago | 1 answer | 0

1

answer

Question


Pneumo-Hydraulic Actuator ports
Hi, I was just wondering why the Pneumo-Hydraulic Actuator does not have a mechanical translational conserving port associated ...

nästan 11 år ago | 1 answer | 0

1

answer

Answered
Error in port widths or dimensions
Thanks Mike, You're right, it should be xo and not x0, stupid mistake! Also I found out that the output variable need to be in...

ungefär 11 år ago | 0

Question


Error in port widths or dimensions
Hi, I do get the following error: Caused by: Error using sldebugui (line 77) Errors occurred during pars...

ungefär 11 år ago | 2 answers | 0

2

answers

Question


Gas accumulator initial pressure
Hi, I'm running a model with a gas accumulator which is connected to several other hydraulic block (pipeline, hydraulic cylin...

mer än 11 år ago | 1 answer | 0

1

answer

Question


State Space with variable parameters
Hi everyone, I'm using Simulink and a State Space Block. I would like to implement some parameters (A, B, C and D) variable at ...

mer än 12 år ago | 1 answer | 0

1

answer

Question


Constant pressure source inferior to Pa
It appears that all pressure in simhydraulics are defined as gauge pressure. Is there any way to set a pressure source in the m...

mer än 13 år ago | 0 answers | 0

0

answers

Answered
Using structures as input of the model with parallel computing
Can anyone help on this topic ?

mer än 13 år ago | 0

Answered
Using structures as input of the model with parallel computing
Thanks for the reply TAB. The problem is I think I have to define my properties in the model workspace as I am using parrallel ...

mer än 13 år ago | 0

Question


Using structures as input of the model with parallel computing
Hi everyone, I'm currently using structure of constants as an input of simulink blocks in my model. The only way I was able t...

mer än 13 år ago | 4 answers | 1

4

answers

Answered
Input of Simulink block used in vector
Any clue someone ?

mer än 13 år ago | 0

Question


Input of Simulink block used in vector
Hi all, I'm using a constant input (actually a strcuture of constant values implemented via a BUS) in a simulink block and I ...

mer än 13 år ago | 1 answer | 0

1

answer

Question


Rename BUS
Hi, I am trying to generate a BUS from a Matlab structure to feed in a Simulink block. I am using this function: FA.cog ...

mer än 13 år ago | 2 answers | 0

2

answers