Question
How to modify Preferences parameters in the Control System Designer app
I would like to run the Control System Designer app with the below configuration by default: Show settling time within 5% Show...
mer än 4 år ago | 1 answer | 0
1
answerQuestion
Simulink Desktop Real Time still having problems
All my Simulink models (External mode) report the following error when I try to execute them. The models use Simulink Deskto...
mer än 5 år ago | 0 answers | 0
0
answersQuestion
Problems to export ScopeData variable to MATLAB 2019a
The ScopeData variable of the Scope block does not appear in the workspace after simulation. I run a Simulink model with the "...
mer än 5 år ago | 0 answers | 1
0
answersQuestion
Problems with the external mode transport layer in Simulink
I receive the error message (attached below) from Simulink related to the "external mode transport layer". It appears in the bui...
mer än 5 år ago | 0 answers | 0
0
answersA Simulink model does not connect to Simulink Desktop Real-Time
Thanks for the answer. The kernel is already install as you comment, but the problem is that sometimes the model connect and so...
nästan 6 år ago | 0
Question
A Simulink model does not connect to Simulink Desktop Real-Time
I have a Simulink model to run in External mode by using the Simulink Desktop Real-Time, with MATLAB R2017b upgrade 8. The build...
ungefär 6 år ago | 2 answers | 0
2
answersQuestion
What does the numerical display of Pidtuner mean?
In the pidTuner menu, there are two displays to the right of Response Time and Transient Behavior sliders that change the numeri...
mer än 6 år ago | 1 answer | 0
1
answerQuestion
Where are the PID blocks in the Block-Specific Parameters in order to change parameters of these blocks in a script?
I am using the PID Controller (2DOF) in a Simulink model. By looking at the Block-Specific Parameters of Simulink, I found that ...
mer än 7 år ago | 1 answer | 0
1
answerQuestion
Real Time windows target 4.5 crash Windows 7
Hi: The Real Time Windows Target of Matlab 2014b generates many blue screen errors in my computers, under 64 bits Windows 7. ...
ungefär 8 år ago | 0 answers | 0
0
answersQuestion
How can I get the points of the Scope block while the simulation is running?
I have a simulink model running in External mode (using the Real-Time Windows Target). And I would like to obtain the points the...
mer än 9 år ago | 1 answer | 0