Statistics
RANK
1 048
of 295 467
REPUTATION
69
CONTRIBUTIONS
14 Questions
43 Answers
ANSWER ACCEPTANCE
42.86%
VOTES RECEIVED
15
RANK
2 516 of 20 234
REPUTATION
675
AVERAGE RATING
5.00
CONTRIBUTIONS
6 Files
DOWNLOADS
101
ALL TIME DOWNLOADS
5894
CONTRIBUTIONS
0 Posts
CONTRIBUTIONS
0 Public Channels
AVERAGE RATING
CONTRIBUTIONS
0 Highlights
AVERAGE NO. OF LIKES
Feeds
Question
C2000 Microcontroller Blockset for TMS320F2800137
Hi, every one, I want to generate the code for TMS320F2800137 uC via MATLAB 2023a. In the MATLAB 2023a, C2000 Microcontroller ...
mer än ett år ago | 1 answer | 2
1
answerControling multiple switches in a multiple input DC-DC converter
Hi Mohamad For pwm generation in simelectronics voltage source are used with internal seting Please gate idea from given below...
mer än ett år ago | 0
What are these blocks in the model power_3phseriescomp?
1. Ya it's simple RLC load. 2. These are used as active and inductive reactive power load. 3. With verying the reactive Power ...
ungefär 2 år ago | 0
Question
Issues on dimension setting of FFT plot in MATLAB 2022a.
Hello everyone, I have got an issue with the dimension setting, level of x-axis, y-axis, font size, style and “minor and major ...
mer än 2 år ago | 1 answer | 0
1
answerHow do I modiify tthe Iout And Vout values so as to Get suitable values for the TEC?
It will depend on the characteristic of variable resistance connected across the input terminal of the peltier device... With i...
mer än 2 år ago | 0
How can I interpolate 13 hour data with each 10 minutes, in every second?
It another solution is done through the 1-D lookup table as atteched simulink file
mer än 2 år ago | 0
Question
How can I interpolate 13 hour data with each 10 minutes, in every second?
Hello every one, I have 13 hour data with every 10 minutes. i want to interpolate it for each seconds how i can do it. data ...
mer än 2 år ago | 2 answers | 0
2
answerslink a full bridge DC/AC to an induction machine
Hello ayoub reffai, In your model you need to connected dc supply for converting DC to AC you have used only voltage and cur...
mer än 2 år ago | 0
Why does differentiating PID feedback break the system?
Hello Janith Wijekoon With increasing sampling time signal gose to nearly continues time mode which requires large memory. More...
mer än 2 år ago | 0
how to do pole to ground fault analysis on dc transmission line
Hi, You can provide pole to ground fault on dc transmission line with the help of circuit breaker connecting between pole and g...
mer än 2 år ago | 0
Where is Switch (Relay) in Simulink?
Hi, You can use two breaker in place of a switch and provide it's external control. To charge the chapacitor one circuit break...
mer än 2 år ago | 0
How do I encode to a TMS320F28335 and see PWM signals live?
Hello ryan, As per your comment, you are able to run the model in external mode,then general the pwm signals As given below...
mer än 2 år ago | 0
Exporting code to CCS, is their any way to observe input adc signal in CCS?
Hi, To observe the ADC input signal of the DSP launchpad on CCS, pls provide a test point to the signals. After that in CCS fol...
mer än 2 år ago | 1
| accepted
Non-linear loads
Hello Mohammed Yakoob, For above you need to use MATLAB Simulink, in Simulink you can devoloped model as atteched picture file....
mer än 2 år ago | 1
| accepted
How to generate deadband between two complimentary pulses of inverter.
Hi, In MATLAB Simulink, deadband can be provided by using dead zone or on/off delay (continuous) or on/off delay (discrete). I...
mer än 2 år ago | 0
Slow simulation of PV system
Hello zenebe, If your system is complex and modelled modelled in continues time domain, then systems performance slow. To mak...
mer än 2 år ago | 0
Why is the settling value of my TF so high when compared to my output value? How can I resolve this?
Hello Samuel Pappalardo Firstly, form your second order characteristics experience in standard form S^2+ 2*zeta*w+ w^2=0 For ...
mer än 2 år ago | 0
how to connect converter circuit devices each other in matlab simulink ?
Some ideas can be obtained from give model as given below link Pemendra Kumar Pardhi (2022). Zeta Converter Based Led Drive...
nästan 3 år ago | 0
how to connect converter circuit devices each other in matlab simulink ?
Hello, Ali Zulfikaroglu The pulse generator output can not connect with the power terminal of any elements (eg. Switch, induc...
nästan 3 år ago | 0
| accepted
introduce dead band time for a complementary signal in TI processor
Hello venkata Kumar, Can you share your Epwm A and Epwm B screenshot. I thik you are obtained just inverted Signal fron EPWM...
nästan 3 år ago | 0
What does these two block in mppt represent?
Hi noble, Fist block represent to unit delay and second block is reapitive sequence generator. The mppt block provides an a...
nästan 3 år ago | 0
F28379D Embedded coder_Sawtooth Wave generation
Hello Raja, To generate sawtooth and triangular waveform, You can try using the Discrete-time alternatives for Repeating Sequ...
nästan 3 år ago | 1
PV ARRay Didoe Rsh Error
Hi, Haris Lateef Chaudhary To resolve this isses, double clik on PV array and go into the advanced, chek the box of break the ...
ungefär 3 år ago | 0
Question
Debug Server Scripting (DSS) error:
Hello, i am trying to interface TMS320F2812 dsp trainer kit with MATLAB 2020b It successfully creates a .out file. However i...
ungefär 3 år ago | 0 answers | 0
0
answersSubmitted
Zeta Converter Based Led Driver Circuit
This circuit is simulated on sim electronics
mer än 3 år ago | 4 downloads |
Model simulink block connection with different simscape
Dear You can connect single phase voltage source from simelectrical-specialized technology- source. In between port 1 and 2 a...
mer än 3 år ago | 1
How to set universal bridge as inverter
Hi, Frank You can use universal bridge as a Inverter or PWM rectifier or uncontrolled rectifier For inverter you must select c...
mer än 3 år ago | 0
Simscape powergui - Invalid dimension specified for input port
Hi Abd Al-Rahman Al-Remal This error occurs due to, you are providing 6 input signals on gate signal of each IGBT, moreover on...
mer än 3 år ago | 1
| accepted
Simulink asynchronous generator voltage input clarification
Hello Dear Abd Al-Rahman Al-Remal The DFIG in wind energy conversion system worked as generator. Therefore it is able to...
mer än 3 år ago | 1
Submitted
Grid-Tied Single Phase Solar Photovoltaic Supply System
This project proposes the control of grid-tied single phase solar photovoltaic supply system (including grid synchronization and...
mer än 3 år ago | 34 downloads |