Error in Simulink

2 views (last 30 days)
Nuno
Nuno on 9 May 2011
what kind of error is this?
"Simscape components in Celula are not connected to a Solver Block." Celula is the name of the program...
  1 Comment
Arnaud Miege
Arnaud Miege on 9 May 2011
Please don't email me directly. As Rob pointed, and as the error message suggests, you need to connect your Simscape network to a Solver Block. I would suggest your read the documentation, in particular the section entitled "Modeling Physical Systems":
http://www.mathworks.com/help/releases/R2011a/toolbox/physmod/simscape/ug/bp5oili.html
Arnaud

Sign in to comment.

Answers (1)

Rob Graessle
Rob Graessle on 9 May 2011
When your block diagram contains Simscape components, the physical network circuit must be connected to at least one Solver Configuration block. This block specifies parameters for the simulation of the physical model.
  1 Comment
Arnaud Miege
Arnaud Miege on 9 May 2011
Actually, it's *exactly* one Solver Configuration per Simscape network.

Sign in to comment.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!