problem with working IF Block
1 view (last 30 days)
Show older comments
In if block subsystem,,,wen a control goes to else condition,,,my if condition subsystem will be reset to '0',,but i dont want it,,,i want to keep hold the last value of if control subsystem,,,anybody know how to make if control subsytem to hold the last calculated value
0 Comments
Accepted Answer
TAB
on 8 Feb 2013
Double click output ports in your if action subsystem and set Output when disabled property to held.
1 Comment
More Answers (0)