Complex to Magnitude-Angle HDL Optimized does not get converted to clock-rate
3 views (last 30 days)
Show older comments
The "Complex to Magnitude-Angle HDL Optimized"-Block I use in order to calculate the atan2 of my alpha and beta components that come from my clarke-transfrom stays at the data-rate. All the other blocks get converted to the clock-rate in the generated-model as intendet by using the option "clock-rate pipelining".
I tried the oversampling factor and defining the sample-rate and data-rate through rate-transitions, either way the result stays identical.
Is there something I'm missing or do I have to force the block to its final sample-time?
1 Comment
Kiran Kintali
on 24 Jul 2020
can you share a sample model with your clock rate pipelining requirements for additional guidance? Thanks
Accepted Answer
Kiran Kintali
on 24 Jul 2020
Edited: Kiran Kintali
on 24 Jul 2020
The "Complex to Magnitude-Angle HDL Optimized" simulates latency in the original model and does not participate in clock rate pipelining where the latency is modeled at the data rate in the original model and hence currently does not participate in clock rate pipelining.
Please consider using CORDIC atan2 block in the Math library in the interim. We will be expanding on the capabilities of CMA block in the near future to support additional features.