why Code generation with model reference initialize port is not working?
20 views (last 30 days)
Show older comments
I tried to analyze initialize port setting in reference model. During model in loop it works fine but its functionality not understanding. During code generation wit ert.tlc and autosar.tlc it is giving below error :
The top model '__________' contains the model block '________' which has one or more of its Initialize, Reset or Terminate ports enabled. Code generated is not supported for such models.
Need c code for reference model initialize port setting to iinitialize function call subsystem. If we use trigger or enable it holds previous value instead of initial output. But we use initialize port with reference model block holds initial value till next change at output.
3 Comments
Binh Huynh Thanh
on 20 Jun 2022
Hello All,
I have a same issue. But I can not underatand why.
Anny one can help. I followed the link : https://www.mathworks.com/help/simulink/ug/build-a-test-harness.html.
But, it can be in simulation mode only. I can not generate the code using embeded coder packages.
Please help us.
Answers (1)
Jesús Zambrano
on 23 Oct 2020
Hi Ranganatha and Samir,
Please follow the steps discribed in the following link:
In there you'll find the workflow to generate code for a model that responds to Initialize, Reset and Terminate events.
Hope it helps!
2 Comments
Samir Revelo
on 23 Oct 2020
Edited: Samir Revelo
on 23 Oct 2020
Hello Jesús,
Thanks for your reply.
As I described in my post above I have actually following limitation (you can find this in link you shared above):
I need that my root model generates code which calls reset function of child refence model.
Is any solution going to be provided for this limitation as this is a use case which I need to handle with Simulink?
Thanks in advance.
Jesús Zambrano
on 23 Oct 2020
Edited: Jesús Zambrano
on 23 Oct 2020
If the child includes explicit ports for Initialize, Reset, Terminate you can't generate code. If you use Initialize, Reset and Terminate function blocks then you can. Outside this workflow you will get a limitation at the moment.