How can I use Simulation Data Inspector (SDI) in External Mode with the TI C2000 Support Package?

1 view (last 30 days)
Hi, I am trying to log simulation data using the TI C2000 Support Package running my model in external mode. I understand I can log packets of data to individual MAT files and stitch them together, or use a scope with "Print to Figure" to extract the signal over the entire simulation. I followed the example listed here:
Is Simulation Data inspector (SDI) supported for this support package in external mode simulations?

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 15 Nov 2023
Edited: MathWorks Support Team on 5 Jan 2024
Yes, SDI is supported for TI C2000 Support Package running in External Mod, but only when running using the Universal Measurement & Calibration (XCP) protocol. "Classic" external mode over USB serial connection does not support SDI.
 
Please run the following command on MATLAB R2018a and refer to the section titled "Monitor and Tune over Serial Communication" in the documentation page:
web(fullfile(docroot, 'supportpkg/texasinstrumentsc2000/target-hardware.html'))
Please follow the below link to search for the required information regarding the current release:

More Answers (0)

Products


Release

R2018a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!