Reference Model replaced by S-Function target code generation
1 view (last 30 days)
Show older comments
If I replace a Referenced Model with a generated S-Function, using the interactive process, I get the expected behaviour for simulation purposes.
However, what I need to do is to generate code for an embedded target (NOT PC) that is based on the ert coder. I can generate the code for the stand-alone model using the ert technique, but it seems like I need a separate mex/tlc combination for target code generateion that would integrate the previously built obj/archive file from the S-Function.
What are the recommended approach to build a model that references these types of S-Functions for target code generation?
0 Comments
Answers (1)
Mark McBroom
on 28 Jan 2019
Why did you replace the reference model with an S-Function. Best approach is to simply generate code for top model with referenced model. Then you don't need to mess around with S-Functions or TLC.
2 Comments
Mark McBroom
on 29 Jan 2019
Yes, Protected Model is the recommended approach to hide model capabilities... however if you allow generating code then you are still exposing model capabilities to users via the resulting C code. Simulation performance with reference models can be sped up by placing the referenced model in Accelerator mode.