If i run PV model in matlab I have face this problem. Pls guide me how to solve this error. if I increase the time 1e-7 simulation is running but very slow.

7 views (last 30 days)
An error occurred while running the simulation and the simulation was terminated Caused by: Simulink cannot solve the algebraic loop containing 'pv970kw/PV Array 1/Diode Rsh/Product5' at time 5.0E-5 using the TrustRegion-based algorithm due to one of the following reasons: the model is ill-defined i.e., the system equations do not have a solution; or the nonlinear equation solver failed to converge due to numerical issues. To rule out solver convergence as the cause of this error, either a) switch to LineSearch-based algorithm using set_param('pv970kw','AlgebraicLoopSolver','LineSearch') b) reducing the VariableStepDiscrete solver RelTol parameter so that the solver takes smaller time steps. If the error persists in spite of the above changes, then the model is likely ill-defined and requires modification.
  2 Comments
keyur acharya
keyur acharya on 28 Mar 2018
Edited: keyur acharya on 28 Mar 2018
hi,were you able to solve the problem? if yes please share the solution. I am also facing the same issue.
Shashank Kumar
Shashank Kumar on 1 Aug 2018
Place a unit delay block in Simulink model between the blocks where algebraic loop occurs. I hope this will help you.

Sign in to comment.

Answers (1)

Shashank Kumar
Shashank Kumar on 1 Aug 2018
Place a unit delay block in Simulink model between the blocks where algebraic loop occurs. I hope this will help you.

Categories

Find more on Schedule Model Components in Help Center and File Exchange

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!