Birdman
Birdman on 13 Oct 2017
Commented: Birdman on 18 Oct 2017
When the code is generated from Speedgoat IO601 blocks, the generated code can not be inlined and from Configuration Parameters, Support non-inlined s-function check have to be made and this results in highly inefficient code. How those s-functions underlying those blocks can be inlined? Is there any other way beside inlining those s-functions and make the code more efficient?

Accepted Answer

Diego Kuratli
Diego Kuratli on 17 Oct 2017
The Support non-inlined s-function option appears for ERT-based targets. This is not related to the IO601 drivers, but generally to the Simulink Real-Time environment.
By default, SLRT uses Tunable parameters, as tuning parameters is one of the main purpose of real-time testing. You can optimize the generated code, by selectively inline parameters: Configuration Parameters -> Optimization -> Signals and Parameters.
  3 Comments
Diego Kuratli
Diego Kuratli on 18 Oct 2017
SLRT is not an ERT-based target. The slrtert.tlc system target file has been removed in recent MATLAB releases. Your concerns about the heavy generated code typically do not apply to the SLRT environment. I suggest you getting in touch with our technical support team for further discussing your specific requirements.
Birdman
Birdman on 18 Oct 2017
Thank you Diego. I think I got it at the moment.