400KHz I2C with Total Phase's Aardvark only transmits at 100KHz
1 view (last 30 days)
Show older comments
I am able to use Total Phase's Aardvark I2C/SPI to send and read data with I2C. However, the transfers only occur at 100KHz with MatLab 2016b in Windows and macOS. I have setup my device as follows:
%%*** initialize i2c channel and unlock i2c slave access
Vendor = 'Aardvark';
BoardIndex = 0;
i2c_dev = i2c(Vendor,BoardIndex,RemoteAddress);
i2c_dev.BitRate = 400;
i2c_dev.PullupResistors = 'none';
i2c_dev.TargetPower = 'none';
set(i2c_dev,'OutputBufferSize',512)
fopen(i2c_dev);
Matlab reports the BitRate set at 400KHz, but proving the bus, all SCL clocks are 100KHz. How do I get to set the bitrate to 400KHz?
Using Total Phase's Control Center, I am able to send commands at 400KHz. Thus, the Aardvark can generate SCL clocks at 400KHz.
Thanks.
0 Comments
Answers (2)
Nikhil Sreekumar
on 5 Oct 2017
Hi Pedro,
Please refer to the bug report below. This addresses the issue that you are facing:
https://www.mathworks.com/support/bugreports/1472060
Thanks
Nikhil
0 Comments
See Also
Categories
Find more on Instrument Control Toolbox in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!