Simulink coder doesn't generate custom storage class code?

1 view (last 30 days)
With the attached model and data dictionary, the generated code still put the parameter p1 in its default header file, although I specified it as custom storage class and should be "ConstVolatile".
What did I miss in the configuration?
Thanks

Accepted Answer

Song
Song on 12 May 2017
change from grt to ert solves this problem.

More Answers (1)

Song
Song on 14 Apr 2017

Categories