Missing Signal Target Scope
2 views (last 30 days)
Show older comments
Hello,
as described above a signal is not displayed numerically on the target pc running simulink realtime (R2015b). Others are displayed in the same scope.
If I try to read out the signal by command prompt (Matlab R2015b):
>> tg.getsignalidsfromlabel('dLambda1')
ans = 335
>> tg.getsignal(335)
Error using xpctarget.xpc/getsignal TargetPC1: Invalid Signal index
Additionally the signal index is higher than the number of signals. I would be a happy for a possible solution / short explanation what is going wrong here.
Thank you in advance.
Best regards Roman
0 Comments
Answers (1)
Hari Desanur
on 12 Dec 2016
You must make sure that the signal which you are trying to monitor is not virtual signal or a virtual bus. You may have to add a 'Gain' block to monitor that signal -