Hi, I don't know why this code is giving me this error.
Initially the output argument E was not used. But I realized I need this value for some stuff I want to do afterwards. Why is it now giving me this error. I never got it before when I used this code with only the three output arguments. Please help!
function [nbar,sig,ChiSqrd,E]=VerifyP_Stats(X)
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% This function takes in counts from a counting experiment, X,
% and performs experimental statistics, as outlined in the
% lab manaual for Radio Active Decay
% (http://physwiki.apps01.yorku.ca/index.php?title=Main_Page/PHYS_3220/Radi
% oactive_Decays).
% It returns the experimental mean (nbar), experimental standard deviation
% (sig), and the chi squared value using the formula for a Poisson
% distribution as outline in the above manual.
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
N=numel(X);
O=ErrorCalc_ObservedK(X);
n=size(O,1);
Pn=linspace(0,0,n);
nPn=linspace(0,0,n);
SigN=linspace(0,0,n);
En=linspace(0,0,n);
preChi=linspace(0,0,n);
for i=1:n
Pn(i)=O(i,2)/N;
nPn(i)=O(i,1)*Pn(i);
end
nbar=sum(nPn);
for i=1:n
SigN(i)=((O(i,1)-nbar)^2)*Pn(i);
En(i)=(N*exp(-nbar)*(nbar)^O(i,1))/factorial(O(i,1));
preChi(i)=((O(i,2)-En(i))^2)/En(i);
end
ChiSqrd=sum(preChi);
sig=sqrt(sum(SigN));
E=En;
end
1 Comment
samjhana rai
on 22 Feb 2021
hello,
im trying to perform to find the optimla placement of the FACTS devices but im getting error as "too many output arguments" i m not sure what the prblem is.
function [fxmin, xmin] = ORPD_30bus()
clc
clear all
warning off all
global Ybus Yf Yt;
%% define named indices into bus, gen, branch matrices
[PQ, PV, REF, NONE, BUS_I, BUS_TYPE, PD, QD, GS, BS, BUS_AREA, VM, ...
VA, BASE_KV, ZONE, VMAX, VMIN, LAM_P, LAM_Q, MU_VMAX, MU_VMIN] = idx_bus;
[F_BUS, T_BUS, BR_R, BR_X, BR_B, RATE_A, RATE_B, RATE_C, ...
TAP, SHIFT, BR_STATUS, PF, QF, PT, QT, MU_SF, MU_ST, ...
ANGMIN, ANGMAX, MU_ANGMIN, MU_ANGMAX] = idx_brch;
[GEN_BUS, PG, QG, QMAX, QMIN, VG, MBASE, GEN_STATUS, PMAX, PMIN, ...
MU_PMAX, MU_PMIN, MU_QMAX, MU_QMIN, PC1, PC2, QC1MIN, QC1MAX, ...
QC2MIN, QC2MAX, RAMP_AGC, RAMP_10, RAMP_30, RAMP_Q, APF] = idx_gen;
[baseMVA, bus, gen, branch, areas, gencost]=case_ieee30; %Input data of IEEE 30 bus test system
% Determine the value of weight change
w_start = 1; %Initial inertia weight's value
w_end = 0.20; %Final inertia weight
w_varyfor = floor(0.7*100);
w_now = w_start;
inertdec = (w_start-w_end)/w_varyfor; %Inertia weight's change per iteration
iter=0;
% Initialize size of Swarm, no. of control varialbes and Velocity
%size of swarm=50 (user may change it), no. of control variables=vg1, vg2,
%vg5,vg8, vg11, vg13 (Generator bus voltage in pu), T1, T2, T3, T4
%(Transformer tap position), QC3, QC10, QC24 (Injected reactive power of
%capacitors in MVAR)
Swarm=[unifrnd(0.90,1.10,50,6),unifrnd(0.95,1.05,50,4),unifrnd(1,20,50,3)];
VStep =[unifrnd(0.04,0.04,50,6),unifrnd(0.002,0.002,50,4), unifrnd(4,4,50,3)];
for i=1:50 % no of particles
global bus gen branch v1 v2 v5 v8 v11 v13
v1=Swarm(i,1);
v2=Swarm(i,2);
v5=Swarm(i,3);
v8=Swarm(i,4);
v11=Swarm(i,5);
v13=Swarm(i,6);
bus(1,VM)=Swarm(i,1);
bus(2,VM)=Swarm(i,2);
bus(5,VM)=Swarm(i,3);
bus(8,VM)=Swarm(i,4);
bus(11,VM)=Swarm(i,5);
bus(13,VM)=Swarm(i,6);
gen(1,VG)=Swarm(i,1); % gen1
gen(2,VG)=Swarm(i,2); %gen2
gen(3,VG)=Swarm(i,3); %gen5
gen(4,VG)=Swarm(i,4); %gen8
gen(5,VG)=Swarm(i,5); %gen11
gen(6,VG)=Swarm(i,6); %gen13
branch(11,TAP)=Swarm(i,7);% T1, transformer tap
branch(12,TAP)=Swarm(i,8); %T2
branch(15,TAP)=Swarm(i,9); %T3
branch(36,TAP)=Swarm(i,10); %T4
bus(3,BS)=Swarm(i,11); % QC3, capacitor
bus(10,BS)=Swarm(i,12); % QC10, capacitor
bus(24,BS)=Swarm(i,13); % QC24, capacitor
global bus gen branch Yf Yt Ybus
[Ybus, Yf, Yt] = makeYbus(baseMVA, bus, branch);% construct Ybus
[MVAbase,bus,gen,branch,success,et]=runpf; % run NR load flow
global V
global Ybus
bbb=branch(:,[PF,QF]).^2; % ans. is P(from)^2, Q(from)^2
ccc=bbb';
ddd=(sum(ccc))';
eee=sqrt(ddd); %actual values of apparent powers "From bus injection"
fff=branch(:,[PT,QT]).^2;
ggg=fff';
hhh=(sum(ggg))';
iii=sqrt(hhh); %actual values of apparent powers "To bus injection"
jjj=[];
for count_1=1:41 % jjj will contain actual max. apparent power.("from" bus power is compared with "to" bus power)
if eee(count_1)>=iii(count_1)
jjj(count_1)=eee(count_1);
else
jjj(count_1)=iii(count_1);
end
end
%penalty value calculation for line flow violations
for count_2=1:41 % max power is compared with thermal limit
if jjj(count_2)>branch(count_2, RATE_A)
kkk(count_2)=10000*((jjj(count_2)-branch((count_2), RATE_A))^2); % if limit violates,penalty is imposed
else
kkk(count_2)=0; %if no violation, penalty is zero
end
end
penalty_line=sum(kkk);% summation of all penalty of line flow violations
%penalty value calculation for bus voltage violation
lll=bus(:,VM); % voltage mag. of each bus
for count_3=1:30
if lll(count_3)>bus(count_3,VMAX)
penalty_volt(count_3)=10000*(lll(count_3)-bus(count_3,VMAX))^2;
elseif lll(count_3)<bus(count_3,VMIN)
penalty_volt(count_3)=10000*(bus(count_3,VMIN)-lll(count_3))^2;
else
penalty_volt(count_3)=0;
end
end
penalty_volt=sum(penalty_volt);%summation of penalty for bus voltage violation
%penalty value calculation for reactive power violation of all
%generators(PV buses and slack bus)
mmm=gen(:,QG);% reactive power output of all generators
for count_4=1:6
if mmm(count_4)>gen(count_4,QMAX)
penalty_reactive(count_4)=10000*((mmm(count_4)-gen(count_4,QMAX))^2);
elseif mmm(count_4)<gen(count_4,QMIN)
penalty_reactive(count_4)=10000*((gen(count_4,QMIN)-mmm(count_4))^2);
else
penalty_reactive(count_4)=0;
end
end
penalty_reactive=sum(penalty_reactive);%summation of penalty for Q limit violation
%penalty value calculation for P violation of slack generator
nnn=gen(:,PG);
if nnn(1,1)>gen(1,PMAX)
penalty_slack=1000*((nnn(1,1)-gen(1,PMAX))^2);
elseif nnn(1,1)<gen(1,PMIN)
penalty_slack=1000*((gen(1,PMIN)-nnn(1,1))^2);
else
penalty_slack=0;
end
%sum of all penalties, penalty function is used to handle inequality
%constraints
global penalty_function
penalty_function=(penalty_slack)+ (penalty_reactive)+(penalty_volt)+(penalty_line);
%sum of real power losses of all branches
global loss
sum_P_loss=(sum(real(loss)));
global penalty_function
fun_Swarm=(sum_P_loss)+(penalty_function);
% Objective function= sum of active power losses of the transmission lines
fSwarm(i,:)=sum_P_loss;
end
% Initializing the Best positions matrix and
% the corresponding function values
PBest = Swarm;
fPBest = fSwarm;
% Finding best particle in initial population
[fGBest, g] = min(fSwarm);
lastbpf = fGBest;
Best = Swarm(g,:); %Used to keep track of the Best particle ever
fBest = fGBest;
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%% THE PSO LOOP %%
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
while( iter < 200 )% no of iterations
global iter
iter = iter+1;
if iter>190
diary on
end
% Update the value of the inertia weight w
if (iter<=w_varyfor) & (iter > 1)
w_now = w_now - inertdec; %Change inertia weight
end
% The PLAIN PSO %
% Set GBest
A = repmat(Swarm(g,:), 50, 1); %A = GBest. repmat(X, m, n) repeats the matrix X in m rows by n columns, 50=no. of particles
% Generate Random Numbers
R1 = rand(50, 13); % 50=No. of particles, 13=dimension of the problem(size of swarm=no. of variables)
R2 = rand(50, 13);
% Calculate Velocity
VStep = w_now*VStep + 2.1*R1.*(PBest-Swarm) + 2.0*R2.*(A-Swarm);% c1=2.1, c2=2
% Apply Vmax Operator for v > Vmax
changeRows = VStep > 0.003;
VStep(find(changeRows)) = 0.003;
% Apply Vmax Operator for v < -Vmax
changeRows = VStep < -0.003;
VStep(find(changeRows)) = -0.003;
% ::UPDATE POSITIONS OF PARTICLES::
Swarm = Swarm + 0.729 * VStep; % Evaluate new Swarm, Chi=0.729
for j=1:50 %no of particles
v1=Swarm(j,1);
v2=Swarm(j,2);
v5=Swarm(j,3);
v8=Swarm(j,4);
v11=Swarm(j,5);
v13=Swarm(j,6);
bus(1,VM)=Swarm(j,1);
bus(2,VM)=Swarm(j,2);
bus(5,VM)=Swarm(j,3);
bus(8,VM)=Swarm(j,4);
bus(11,VM)=Swarm(j,5);
bus(13,VM)=Swarm(j,6);
gen(1,VG)=Swarm(j,1); % gen1
gen(2,VG)=Swarm(j,2); %gen2
gen(3,VG)=Swarm(j,3); %gen5
gen(4,VG)=Swarm(j,4); %gen8
gen(5,VG)=Swarm(j,5); %gen11
gen(6,VG)=Swarm(j,6); %gen13
branch(11,TAP)=Swarm(j,7);% T1, transformer tap
branch(12,TAP)=Swarm(j,8); %T2
branch(15,TAP)=Swarm(j,9); %T3
branch(36,TAP)=Swarm(j,10); %T4
bus(3,BS)=Swarm(j,11); % QC3, capacitor
bus(10,BS)=Swarm(j,12); % QC10, capacitor
bus(24,BS)=Swarm(j,13); % QC24, capacitor
[Ybus, Yf, Yt] = makeYbus(baseMVA, bus, branch);
[MVAbase,bus,gen,branch,success,et]=runpf;
global V
bbb=branch(:,[PF,QF]).^2; % ans. is P(from)^2, Q(from)^2
ccc=bbb';
ddd=(sum(ccc))';
eee=sqrt(ddd); %actual values of apparent powers "From bus injection"
fff=branch(:,[PT,QT]).^2;
ggg=fff';
hhh=(sum(ggg))';
iii=sqrt(hhh); %actual values of apparent powers "To bus injection"
jjj=[];
for count_1=1:41 % jjj will contain actual max. apparent power.("from" bus power is compared with "to" bus power)
if eee(count_1)>=iii(count_1)
jjj(count_1)=eee(count_1);
else
jjj(count_1)=iii(count_1);
end
end
%penalty value calculation for line flow violations
for count_2=1:41 % max power is compared with thermal limit
if jjj(count_2)>branch(count_2, RATE_A)
kkk(count_2)=10000*((jjj(count_2)-branch((count_2), RATE_A))^2); % if limit violates,penalty is imposed
else
kkk(count_2)=0; %if no violation, penalty is zero
end
end
penalty_line=sum(kkk);% summation of all penalty of line flow violations
%penalty value calculation for bus voltage violation
lll=bus(:,VM); % voltage mag. of each bus
for count_3=1:30
if lll(count_3)>bus(count_3,VMAX)
penalty_volt(count_3)=10000*(lll(count_3)-bus(count_3,VMAX))^2;
elseif lll(count_3)<bus(count_3,VMIN)
penalty_volt(count_3)=10000*(bus(count_3,VMIN)-lll(count_3))^2;
else
penalty_volt(count_3)=0;
end
end
penalty_volt=sum(penalty_volt);%summation of penalty for bus voltage violation
%penalty value calculation for reactive power violation of all
%generators(PV buses and slack bus)
mmm=gen(:,QG);% reactive power output of all generators
for count_4=1:6
if mmm(count_4)>gen(count_4,QMAX)
penalty_reactive(count_4)=10000*((mmm(count_4)-gen(count_4,QMAX))^2);
elseif mmm(count_4)<gen(count_4,QMIN)
penalty_reactive(count_4)=10000*((gen(count_4,QMIN)-mmm(count_4))^2);
else
penalty_reactive(count_4)=0;
end
end
penalty_reactive=sum(penalty_reactive);%summation of penalty for Q limit violation
%penalty value calculation for P violation of slack generator
nnn=gen(:,PG);
if nnn(1,1)>gen(1,PMAX)
penalty_slack=1000*((nnn(1,1)-gen(1,PMAX))^2);
elseif nnn(1,1)<gen(1,PMIN)
penalty_slack=1000*((gen(1,PMIN)-nnn(1,1))^2);
else
penalty_slack=0;
end
%sum of all penalties
global penalty_function
penalty_function=(penalty_slack)+ (penalty_reactive)+(penalty_volt)+(penalty_line);
%sum of real power losses of all branches
global loss
sum_P_loss=(sum(real(loss)))
global penalty_function
fun_Swarm=(sum_P_loss)+(penalty_function);
fSwarm(j,:)=sum_P_loss;
end
% Updating the best position for each particle
changeRows = fSwarm < fPBest; % latest fswarm-previous fswarm
fPBest(find(changeRows)) = fSwarm(find(changeRows)); %fitness value
PBest(find(changeRows), :) = Swarm(find(changeRows), :); %position
lastbpart = PBest(g, :);
% Updating index g
[fGBest, g] = min(fPBest);
%Update Best. Only if fitness has improved.
if fGBest < lastbpf
[fBest, b] = min(fPBest);
fbest(iter) = fBest;
figure(1);
plot(fbest, '-b' );
title('Total Active power losses (MW)');
xlabel('Iteration number');
ylabel('Total Active power losses (MW)');
fBest;
Best = PBest(b,:);
end
end
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%% END OF PSO LOOP %%
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
[fxmin, b] = min(fPBest)
xmin = PBest(b, :)
%diary off
return
please do comment if anyone of you know.
Accepted Answer
Star Strider
on 21 Oct 2015
Usually, the ‘too many output arguments’ error occurs in your calling script, when you ask for more outputs than the function provides. My guess is that you either have a copy of your previous function (with three outputs) in another directory and your new script code is calling it instead, or that you have a variable in your script called ‘VerifyP_Stats’. The easiest way to solve the problem of two functions having the same name is to rename one of them (for example call this one ‘VerifyP_Stats4’ or something), and change your call to it.
An easy way to see if you are shadowing ‘VerifyP_Stats’ with another function or a variable is to enter this in the Command Window:
which VerifyP_Stats -all
The results will tell you.
I don’t have your code, so I’m purely guessing.
3 Comments
Star Strider
on 21 Oct 2015
My pleasure!
I’m surprised which didn’t find both. It only looks on the MATLAB search path, so there is a possibility that the other directory isn’t on it. See the documentation for addpath (and its friends) for details on including all the directories you want MATLAB to know about.
More Answers (0)
See Also
Categories
Find more on Get Started with MATLAB in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!