Modelling shell and tube heat exchanger
61 views (last 30 days)
Show older comments
Respected fellas: please help me in modelling a 1 shell 2 pass heat exchanger in simulink? that is i know the flowrate value of both the hot and the cold fluids, their initial temperatures. I am having problems with the heat transfer coefficient, if you help me in modelling its well and good otherwise its value will be assumed.the thing i want is the "final temperature of the hot fluid" as it leaves the heat exchanger at each instant. (keeping in mind that the "heat transfer" and the "heat transfer coefficient" is changing every instant)
Answers (1)
Yifeng Tang
on 22 Jun 2022
If you are trying to model the heat exchanger using the blocks only from the foundation library, you may will need to modify the correlation for convective heat transfer between the pipe wall and the fluid. This means making a custom pipe block based on the library version. The default Gnielinski correlation may not match the heat exchanger you have very well.
If you have access to a newer version of Simscape Fluids, there are a few heat exchanger blocks available and the list is expanding. There are a few "system-level" heat exchangers, which allow you to provide a set of nominal working conditions, and the block will extrapolate to other conditions. The extrapolation may be tuned via the coefficients for the Nusselt number correlation, if data for more working conditions are available.
0 Comments
See Also
Categories
Find more on Upgrading Hydraulic Models to Use Isothermal Liquid Blocks in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!