Control Techniques for PMSM
Show older comments
Currently I'm Taking Control Techniques for PMSM (new), at Current Controller Optimization, Implement MTPA and FWC to optimize your controller. I start taking the task, from 1 to 3 all no issues, but when I take the task 4, and follow the step by step, and checked all the setting are fine, but the output not meet the requirement, checked no error log, please help,

2 Comments
Kartikey
on 12 Oct 2026 at 10:36
The screenshot is too zoomed out, so it is difficult to identify the exact cause. As a troubleshooting step, remove the current Vector Concatenate block and add a new one with Number of inputs set to 3. Reconnect the signals and check whether the assessment passes.
Signal Assessment appears to be connected to the V_ao output of the PWM Reference Generator. Verify this connection and the block parameters. Use the task’s Hint section to compare the expected setup with your model.
Answers (1)
Kartikey
5 minutes ago
0 votes
From page 9 of the attached PDF, I noticed a possible angle-unit mismatch. The Input mechanical angle unit parameter of the Mechanical to Electrical Position block is set to Radians, so its electrical-position output is also in radians. However, the Theta units parameter of the SinCos Embedded Optimized block is set to Per-unit.
Could you try changing the Theta units parameter to Radians, rerunning the model, and submitting the task again? I think this may resolve the mismatch. Let me know whether the assessment passes after the change.