Spectrum block shows incorrect dbm value
Show older comments
Dear all,
In the attached model NCO generates a sine wave of 32MHz and spectrum is set to RBW of 1MHz, 50Ohm resistance. We can see in the Spectrum, that the peak value in dbm is 6.9823, which corresponds to a peak-to-peak voltage of 1.413V. However, in the scope block we can see, that the signal amplitude is 2V peak-to-peak, which corresponds to 10dbm (dbm = 10*log10(1000*Vrms^2/R)). Why so?
The model is attached.


Thank you!
4 Comments
Sergei
on 26 Jun 2025
Mathieu NOE
on 30 Jun 2025
funny
the difference you mention is exactly 3 dB (as if you swap Vpeak vs a Vrms value = sqrt(2) factor for a sine wave)
Mathieu NOE
on 1 Jul 2025
hello
"funny" was maybe not the most appropriate word, I was just suggesting that there is somewhere a mistake as somewhere we use Vrms instead of Vpeak and that's why we see a 3 dB difference
but as I can't open your slx file (because I run R2020a release) I can't say for sure where the confusion may come from
Accepted Answer