Hello,
I am doing setup of Configuration Parameters.
Based on "Code Generation Advisor" output, I have to fix few parameters. Issue arises when I try to find them, they are not available.
I use ert_custom.tlc, which is based on the built-in ert.tlc. Only difference is that I removed suffix of the generated folder.
Original "Configuration Parameters" are stored in the dictionary which is linked to the model I use.
I am facing the following issues:
  • Build configuration -> grayed out, not changable
  • Combine signal/state structures (CombineSignalStateStructs) -> not available in the dialog
  • non-finite numbers (SupportNonFinite) -> not available in the dialog

2 Comments

Could you share the Simulink file along with the ert_custom.tlc file? This would allow me to reproduce the issue and investigate the root cause of it.
Because of the confidentiality, I couldn't share original project.
But, in attachments, there is a simple project based on the original one in terms of the config structure, where the issue is reproducible.

Sign in to comment.

 Accepted Answer

Hi Djordje,
The error you encountered is due to the ert_custom_issue.tlc file. The .tlc file that you have shared was having "rtwgensettings.BuildDirSuffix" set to empty which was causing these options to be disabled. You have to modify the " rtwgenSettings" structure to inherit options from the ERT target, then you will get "CombineSignalStateStructs","SupportNonFinite" and "Build configuration" options enabled. Refer to the below code:
rtwgensettings.BuildDirSuffix = '_ert_custom_issue_rtw';
rtwgensettings.DerivedFrom = 'ert.tlc';
rtwgensettings.Version = '1';
For more information on "Create ERT-Based, Toolchain Compliant System Target File" refer to the below MATLAB documentation,

1 Comment

Hello @Hitesh,
Thanks for your clarifications.
I made BuildDirSuffix empty in order to remove suffix of the directory where code is generated. This is requirement from the project, in order to have the history of the generated code independent of the type of generation.
I made the following changes, and now everything except "Build configuration -> grayed out, not changable" works. But, it is totally acceptable.
So, final changes in customized .tlc file are:
rtwgensettings.BuildDirSuffix = '';
rtwgensettings.DerivedFrom = 'ert.tlc';
rtwgensettings.Version = '1';
BR,
Djordje

Sign in to comment.

More Answers (0)

Categories

Find more on Deployment, Integration, and Supported Hardware in Help Center and File Exchange

Products

Release

R2024a

Asked:

on 16 Oct 2024

Commented:

on 21 Oct 2024

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!