How do I connect PS Variable Delay Block to a Constant Current Load block

4 views (last 30 days)
How do I connect PS Variable Delay Block to a Constant Current Load block? I would like to add a delay to 120 degrees.

Accepted Answer

Sumukh
Sumukh on 25 Jul 2024
Hi David.
I understand that you are trying to introduce a delay of 120 degrees to the current through the load. However, the constant current load block cannot be connected to PS blocks, as it can only be used with electrical circuits, for use with DC or AC sources, as provided in the documentation:
Introducing a delay directly in the Simscape Electrical based circuit is not possible. The PS-Variable delay block can, however, introduce a delay to physical signals or sources, passed as input to the controlled voltage or current source blocks, available in Simscape Electrical. These sources can then be used with the constant current load block in the electrical circuit.
I hope this solves your issue.

More Answers (0)

Categories

Find more on Simscape Electrical in Help Center and File Exchange

Products


Release

R2024a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!