Clear Filters
Clear Filters

How to resolve error ""Error:The storage class of the signal connected to 'Output Port 1' of 'autosarTe​stMdl/Subs​ystem/Even​t Receive' is global, thus the generated code is not reusable." when generating AUTOSAR Adaptive code in R2024a?

1 view (last 30 days)

I am getting this error when generating code with AUTOSAR Blockset for AUTOSAR Adaptive:

"Error:The storage class of the signal connected to 'Output Port 1' of 'autosarTestMdl/Subsystem/Event Receive' is global, thus the generated code is not reusable. Consider using storage class 'Auto', setting Code interface packaging to 'Nonreusable function', or setting Multi-instance code error diagnostic to 'None' or 'Warning'"
How to fix it?

Accepted Answer

MathWorks Support Team
MathWorks Support Team on 17 May 2024
Currently the only option to resolve this is mentioned in the error message itself. The diagnostic option cannot be set to None or Warning using the Configuration UI, which is why you need to use the Simulink API:
set_param(bdroot,'MultiInstanceErrorCode','None')

More Answers (0)

Categories

Find more on AUTOSAR Blockset in Help Center and File Exchange

Tags

No tags entered yet.

Products


Release

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!