scope displays incorrect waveforms

1 view (last 30 days)
思雨
思雨 on 9 May 2024
Commented: 思雨 on 10 May 2024
Using the Repeating Sequence Stair module, when monitoring the waveforms, we found that the output waveforms were not strictly step signals, but had a slight slope as they changed.

Accepted Answer

Fangjun Jiang
Fangjun Jiang on 9 May 2024
It is a discrete/digital simulation. There is always a time interval (however small) between two values. Turning on Marker at the Scope block (View, Style, Marker) will show the data points. Reducing the simulaiton step size will make the slope steeper.
  1 Comment
思雨
思雨 on 10 May 2024
Thank you very much, your method worked and helped me solve my problem, thanks!