I want to use a solenoid valve to achieve two-phase flow on/off

8 views (last 30 days)
Hello,I want to use a solenoid valve to achieve two-phase flow on/off, I tried to use the Orifice (2P) module, but its cross-flow area cannot be set to 0 to be fully on/off.

Answers (1)

Yifeng Tang
Yifeng Tang on 2 Jan 2024
First, you'll almost never see a valve block to be complete "off" in a model. You'll always see a minimum area or flow fraction. This is to avoid a sudden change to the systems of equations in the middle of a simulation, so there is some good numerical reason behind this. Also, physically, a valve is never fully "off". Leakage is real. As long as the leakage is a neglible amount, you may consider the valve off.
Now, to your question. The Orifice (2P) block from the Simscape Fluids library is the right one to use. Its equations are a bit more robust than the ones in the Local Restriction block. I tends to get more stable results from Orifice (2P).

Categories

Find more on Two-Phase Fluid Library in Help Center and File Exchange

Products


Release

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!