Clear Filters
Clear Filters

PMSM current controller Vph max limit

7 views (last 30 days)
Sriram M A
Sriram M A on 14 Feb 2023
Answered: Sabin on 16 Feb 2023
Hello,
In the PMSM FOC model, Inside the current loop, Vph max input to the current controller is given as Vdc/(root 3) . Is there a specific reason for using this value or is it dependant on what control scheme you are using . Incase im using SVPWM control what value should i use as Vph max .
Thank you

Accepted Answer

Sabin
Sabin on 16 Feb 2023
Hi, VphMax is dependent on the modulation technique used. If we have Space Vector Modulation the maximum amplitude of the phase voltage is Vdc/sqrt(3). If we have Sinusoidal Modulation then VphMax=Vdc/2. The maximum amplitude can be increased in the overmodulation region, for example in six-step operation we can get (2/pi)*Vdc. I hope this helps.

More Answers (0)

Categories

Find more on Simulink in Help Center and File Exchange

Products


Release

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!