Simulink ADD block keeps returning 255

So I have two inputs 'Pre-State' and 'Pre-Status'. The values going into the ADD block are '1' and '0' respectively, yet for some reason the ADD block keeps returning 255.
The ADD block is setup so that 'Pre-Status' is subtracting 'Pre-State'. So in theory, the output should be -1. Yet it keeps giving 255 for some reason.

1 Comment

Some settings are not right. You have to show it. I guess it is the data type of the output and the saturation flag.

Sign in to comment.

Answers (1)

My guess is that Sum block's output data type is uint8, and the block is configured to wrap on integer overflows.
So the output would be module 2^8 of the "ideal output result".
idealOutput = -1
idealOutput = -1
actualOutput = mod(idealOutput, 256)
actualOutput = 255
We could also test this theory with Fixed-Point Designer fi objects.
nt = numerictype('uint8')
nt = DataTypeMode: Fixed-point: binary point scaling Signedness: Unsigned WordLength: 8 FractionLength: 0
fiOutput = fi( idealOutput, nt, 'OverflowAction', 'Wrap', 'RoundingMethod', 'Floor')
fiOutput =
255 DataTypeMode: Fixed-point: binary point scaling Signedness: Unsigned WordLength: 8 FractionLength: 0 RoundingMethod: Floor OverflowAction: Wrap ProductMode: FullPrecision SumMode: FullPrecision