Is it possible to pass simulink NMPC parameters as struct?
6 views (last 30 days)
Show older comments
Eduardo
on 21 Nov 2022
Commented: Osamah Ali Mohammed Saad
on 5 Mar 2024
Currently I am developing a NMPC controller and the functions used for the algorithm (state definition, cost, etc.) make use or a broad array of parameters.
In Matlab I have used a structure to pass the parameters without problem, e.g.:
p.param1 = 2
p.param2 = 3
p.param3 = 4
nloptions = nlmpcmoveopt
nloptions.Parameters = {p} % <--- works without a problem with nlmpcmove
While implementing the controller on Simulink I have found that the parameters should be given using a "Bus Creator" which should be predefined in Matlab with createParameterBus. This doesn´t allow the use of "struct".
I tried encapsulating my structure in a cell array but to no avail. When using my structure as a constant to the bus creator I get the following error:
Invalid setting in 'Bus Creator1' for parameter 'OutDataTypeStr'.
Caused by:
Error evaluating properties of Simulink.Bus object 'busNPC_2' in workspace 'base' (used by block 'Bus Creator1')
Error evaluating DataType property.
Not enough input arguments.
Component:Simulink | Category:Block error
If I cannot use the structure I would have to pass the parameters separately to the functions (e.g. fun1(x,u, p1, p2, p3, p4, .......))
This would be rather bothersome and unappealing.
Any help/suggestions provided are really appreciated :)
4 Comments
Accepted Answer
More Answers (0)
See Also
Categories
Find more on Linear Plant Specification in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!