how to write hourly varying load consumption data in matlab code for ieee 33 bus system to get current values and losses
38 views (last 30 days)
Show older comments
i am working on IEEE 33 bus system and i have static load data so that i want use dynamic data like hourly load consumption data to get current values and losses for proposed test system,hence i request please guide me to writing the code in matlab
2 Comments
Lonah Segera
on 4 Apr 2023
Dear Saleh Ba-swaimi. Could you please help me, I am working on the IEEE 15 bus and I need to represent the bus load data in hourly format but I don't know how to do it.
Answers (1)
Thomson Mtonga
on 28 Jun 2023
Dear sameer mohammad,
For a start, try running the attached file "UntitledElpa". It plots the load variations as are given in:
clc;
clear all;
format long
Industrial = [6:1:18];
Residential = [2,3,4,5,19,20,21,22,23,24,25];
Commercial = [26,27,28,29,30,31,32,33];
mpc = case33Loss202;
mpc.bus(2,3)
LoadVariInd = [0.56;0.54;0.52;0.50;0.55;0.58;0.68;0.80;0.90;0.98;1.00;0.94;0.95;0.96;0.90;0.83;0.78;0.72;0.71;0.70;0.69;0.67;0.65;0.60];
LoadVariRes = [0.69;0.65;0.62;0.56;0.58;0.61;0.64;0.76;0.9;0.95;0.98;1;0.99;0.99;1;0.96;0.96;0.94;0.93;0.92;0.91;0.88;0.84;0.72];
LoadVariCom = [0.2;0.19;0.18;0.18;0.2;0.22;0.25;0.4;0.65;0.86;0.9;0.92;0.89;0.92;0.94;0.96;1;0.88;0.76;0.73;0.65;0.5;0.28;0.22];
for i=1:length(Industrial(1,:))
AA(i,:)=(mpc.bus(Industrial(1,i),3))*1e3;
BB(i,:)=(mpc.bus(Industrial(1,i),4))*1e3;
end
for i=1:length(Residential(1,:))
AA1(i,:)=(mpc.bus(Residential(1,i),3))*1e3;
BB1(i,:)=(mpc.bus(Residential(1,i),4))*1e3;
end
for i=1:length(Commercial(1,:))
AA2(i,:)=(mpc.bus(Commercial(1,i),3))*1e3;
BB2(i,:)=(mpc.bus(Commercial(1,i),4))*1e3;
end
P = sum(AA);
Q = sum(BB);
S = (P^2+Q^2)^0.5;
P1 = sum(AA1);
Q1 = sum(BB1);
S1 = (P1^2+Q1^2)^0.5;
P2 = sum(AA2);
Q2 = sum(BB2);
S2 = (P2^2+Q2^2)^0.5;
for j=1:length(LoadVariInd(:,1))
Demand(j,:)=LoadVariInd(j,:)*S;
Demand1(j,:)=LoadVariRes(j,:)*S1;
Demand2(j,:)=LoadVariCom(j,:)*S2;
end
E=max(Demand);
E1=max(Demand1);
E2=max(Demand2);
Demand=Demand/E;
Demand1=Demand1/E1;
Demand2=Demand2/E2;
graph=plot([1:length(LoadVariInd(:,1))],Demand, '-oy',[1:length(LoadVariInd(:,1))],Demand1, '-og',[1:length(LoadVariInd(:,1))],Demand2, '-ob');
legend('Industrial Load Profile', 'Residential Load Profile', 'Commercial Load Profile');
set(graph,'LineWidth',1.3);
xlabel('Time (h)');
ylabel('Demand (p.u.)');
xlim([1 24]);
ylim([0 1]);
grid on;
Optimal Placement and Sizing of D-STATCOM in Radial and Meshed Distribution Networks Using a Discrete-Continuous Version of the Genetic Algorithm By Cristian Mateo Castiblanco-Pérez, David Esteban Toro-Rodríguez, Oscar Danilo Montoya and Diego Armando Giral-Ramírez
3 Comments
Daravann MEL
on 15 Sep 2023
Dear Mr. Thomson
I am sory in advance If I call you Last name.
Thank you for your sharing.
However, I have some question that is related to your code for the following point?
1, How did you know or select bus for residential, commercial, and industrial?
2, How did you know load variation (load factor) for those 3 load type?
sevgi
on 9 Oct 2024
Dear Mr. Thomson
How can I perform a 24-hour power flow analysis (bus voltages, line currents, etc.) of a 33-bus radial distribution system?
See Also
Categories
Find more on Weather and Atmospheric Science in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!