Scope in Simulink does not display waveform correctly

Hello!
In Simulink I implement a very simple circuit with an AC voltage source (110kV,50Hz) in series with a Resistance R=1 Ohm and PowerGUI set to Discrete (Ts=5e-5s). I use also a "voltage measurement" block and a Scope to display the voltage waveform of the source. When I set the "Stop simulation time" to 0.2s the waveform is displayed from 0 to 0.2s as it was expected but when I set it to 0.4s it starts from around 0.15s (???). The same behavior occurs when I just use "Sine wave function" block with a Scope. There is something wrong with the scope because when I plot through the workspace everything is ok.
I would be grateful if somebody has a solution on this issue and could share it!
Regards, Michail

 Accepted Answer

I suppose your sample time is very small, in the scope parameters-history uncheck limit data point to last

2 Comments

Perfectly right! Thank you very much for your help!

Sign in to comment.

More Answers (1)

Products

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!