Simulink Build Error : Type mismatch in initial value
14 views (last 30 days)
Show older comments
I was getting build error as below, when I did not match the Data types.
Invalid output port data type. Data type of 'Output Port 4' of 'Integrated_HAL_BSW_ASW_ver1_05/BSW_ASW_Interface_INPUT/ASW to BSW Interface/Bus Selector1' is invalid.
The below picture shows the problematic area of my model. The output of the Stateflow is linked to the Bus selector.
Then I managed to match the data types, but now I am receiving the below error.
Type mismatch in initial value. Data 'PumpBatWp1Out_RPM' is set to be of type 'uint8' and its initial value '0' evaluated to type 'double'.
If I also have to match the initial value data type, how can I change the initial value data type? Please help me to solve this.
Thank you
0 Comments
Answers (1)
Stefanie Schwarz
on 15 Dec 2022
Edited: Stefanie Schwarz
on 15 Dec 2022
Could you try to specify uint8(0) instead of just "0" as the initial value for 'PumpBatWp1Out_RPM' in the Stateflow Symbols Pane > Property Inspector? Otherwise, it is assumed that the 0 is double.
More information on setting data properties for Stateflow:
More information on specifying Stateflow chart data properties using MATLAB Expressions can be found here:
0 Comments
See Also
Categories
Find more on Simulink Functions in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!