Clear Filters
Clear Filters

Get exact value from Scope cursor in Simulink

23 views (last 30 days)
I am using the vertical Cursors in a Scope window to find the signal value. However, the value only displays three significant numbers behind the comma. In my example, it shows 2.202e+07:
Can I get the signal value with more significant numbers somehow? The signal in this case is actually a uint32 signal where each bit represents something, so I need to get the exact uint32 value.

Accepted Answer

Sahil Jain
Sahil Jain on 2 Sep 2021
Hi Jonas. As of R2021a, it is not possible to increase the number of digits shown in the Scope block window. As a workaround, you can export the signals to the workspace (see "to workspace" block) and use the "format" function to set the format style to 'long' and print the values to the console.
  2 Comments
Controls Engineer
Controls Engineer on 2 Aug 2023
Hi Sahil, is there a plan to meet this requirement in a future release? Given the number of views within the last 30 days, it would seem many people are disappointed in this loss of functionality and have searched for a solution. "to workspsace" is not a viable long term solution when needing to quickly analyze signals.
Jack
Jack on 29 Aug 2024
This should be fixed. It isn't a limitation, just a weird decision.

Sign in to comment.

More Answers (0)

Categories

Find more on Event Functions in Help Center and File Exchange

Products


Release

R2020b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!