Is it possible to specify a dynamic value for the Integrator block's "Upper Saturation Limit" parameter using an external input?
    11 views (last 30 days)
  
       Show older comments
    
    MathWorks Support Team
    
 on 8 Oct 2013
  
    
    
    
    
    Edited: MathWorks Support Team
    
 on 20 Sep 2022
            The Integrator block has an "Upper Saturation Limit" parameter that denotes the upper limit for the integral. I would like to specify a dynamic value for this parameter using an external input to the Integrator block, such that its value is computed by other blocks in my model.
Accepted Answer
  MathWorks Support Team
    
 on 20 Sep 2022
        
      Edited: MathWorks Support Team
    
 on 20 Sep 2022
  
      The ability to use an external input to specify a dynamic value for the built-in Integrator block's "Upper Saturation Limit" parameter is not available in Simulink.
To work around this issue, you can use core Simulink blocks to build your own integrator block that allows you to specify dynamic values for its parameters. See the attached Simulink model, named continuous_integrator.mdl, for an example that demonstrates a custom integrator block with external inputs for its "Upper Saturation Limit" and "Lower Saturation Limit" parameters.
0 Comments
More Answers (0)