Answered
How can I get the error message from sldvrun when programmatically using Simulink Design Verifier?
Hi Monika, Apologies for the delay. You can use the ERRMSGS return field with sldvcompat: [STATUS, ERRMSGS] = sldvcompat(...

mer än ett år ago | 0

| accepted

Answered
Why do I get dead-logic on transitions which can be excited through some test scenarios?
Hi Ilkay, Great question. We have seen similar cases to this. Here is what is happening: In each case, we have (taking ...

nästan 2 år ago | 0

| accepted

Answered
How to collect cumulative coverage for model and it's subsystem?
We added a feature in R2019b to enable "aggregated" coverage for a model and its subsystems. Does this help? https://www.mathwor...

ungefär 2 år ago | 0

| accepted

Answered
Design Verifier: Does multiple dimensions input has great influence in test generation?
Hi Jiahao, This will likely be difficult to solve via MATLAB Answers. If you are able to share a bit more detail, could you ...

mer än 2 år ago | 0

Answered
How do I collect coverage for a MATLAB System block in Simulink?
MATLAB System objects can receive Decision, Condition, and MCDC when they are configured to simulate using Code Generation. In ...

mer än 2 år ago | 0

| accepted

Question


How do I collect coverage for a MATLAB System block in Simulink?
I was running the Generate Code for Lane Marker Detector example , which has a MATLAB System block in it, and was only able to c...

mer än 2 år ago | 1 answer | 0

1

answer

Answered
how does the simulink design verifier creates test case
Hi Ajay, There is an option to "extend" existing test cases with Simulink Design Verifier: https://www.mathworks.com/help/sld...

mer än 2 år ago | 0

| accepted

Answered
How to remove top phrases from a word cloud
The removeWords function only removes specific words. It won't remove phrases like you might expect. The word clouds are sho...

mer än 2 år ago | 0

| accepted

Question


How to remove top phrases from a word cloud
I have created a set of word clouds, but want to remove some common two-word phrases that appear in each. I tried using removeW...

mer än 2 år ago | 1 answer | 0

1

answer

Answered
Cumulative coverage for different test cases
(To officially answer this) For cumulative coverage workflows, you can create a test harness for the system under test using ...

mer än 2 år ago | 0

| accepted

Answered
How do I extract the contents of an HTML table on a web page into a MATLAB table?
You can extract the <table> content, which is all stored in a set of <td> tags, as a string array and go from there. You first ...

mer än 2 år ago | 3

| accepted

Question


How do I extract the contents of an HTML table on a web page into a MATLAB table?
I'd like to plot and analyze the TSA traveler data from this website: https://www.tsa.gov/coronavirus/passenger-throughput The ...

mer än 2 år ago | 2 answers | 0

2

answers

Answered
Design verifier :run all and produce coverage for a sldvmakeharness created model
Hi Jiahao, I recommend using sldvrun to generate tests with Design Verifier, then sldvruntest to run the tests and cvhtml to ...

mer än 2 år ago | 0

| accepted

Answered
Simulink Block not executed
Hi Ajay, The coverage report should show the decision coverage achieved for that block. I assume the block you are referring ...

mer än 2 år ago | 0

| accepted

Answered
Retrieve child coverage results from parent model
Hi Luis, Thanks for your question. You are correct in that the signal range coverage is not collected for model outputs. The...

mer än 2 år ago | 1

Answered
How can I input expected output values for a signal to simulink design verifier and generate tests with it?
Hi Xinkun, Thank you for your question. I recommend you use a Test Objective block, which you can use to define a desired ...

nästan 3 år ago | 0

Answered
Don't know why SLDV checks compatibility fail
Hi galaxy, I spoke with the SLDV Development team. This may be due to an internal error within the tool. It will require re...

ungefär 3 år ago | 0

Answered
How do I extract all rows of a struct field that is a character array?
First, try to avoid using character arrays. Convert them to string arrays. Second, you need to use the {curly brace syntax} to ...

ungefär 3 år ago | 3

| accepted

Question


How do I extract all rows of a struct field that is a character array?
I want to extract all rows of a field within a struct. The field is a character array. For sake of example, the struct is calle...

ungefär 3 år ago | 1 answer | 1

1

answer

Answered
2019b toolbox verification
As Walter already answered, the Simulink Verification and Validation product was split into three products. The Simulink Veri...

ungefär 3 år ago | 0

Question


How do I check for unresolved requirements links programmatically?
I would like to check for any "bad" requirements implementation links as part of a Continuous Integration (CI) workflow. For ex...

ungefär 3 år ago | 1 answer | 0

1

answer

Answered
How do I check for unresolved requirements links programmatically?
This can be accomplished using the isResolved method within the slreq.Link class. You can also use the isResolvedSource and i...

ungefär 3 år ago | 0

| accepted

Answered
How do I create a coverage filter for all Simulink blocks with a given Tag?
One way to do this is to use find_system to build a list of all Simulink blocks with a given tag. Then, you can use BlockSelect...

mer än 3 år ago | 0

| accepted

Question


How do I create a coverage filter for all Simulink blocks with a given Tag?
I would like to create a model coverage filter for all Simulink blocks with a given Tag. I didn't see a way to do this with the...

mer än 3 år ago | 1 answer | 0

1

answer

Answered
How do I import a test harness with an existing model reference?
One way to do this is through sltest.harness.import, which allows you to import a stand-alone model as a test harness model. If...

mer än 3 år ago | 0

| accepted

Question


How do I import a test harness with an existing model reference?
I accidentally "disassociated" a test harness model with its parent model. What is the easiest way to re-associate the harness m...

mer än 3 år ago | 1 answer | 0

1

answer

Answered
Simulink Design Verifier Support
Hi Logan, Apologies for the delay in my response (I was away on leave and my MATLAB Answers RSS feed is somehow broken). Thi...

mer än 3 år ago | 0

Answered
Why is a Simulink Check license checked out when I open a model?
This is likely due to Edit-Time Checking being enabled on the model. If the model has been saved with Edit-Time Checking enabled...

mer än 3 år ago | 0

| accepted

Question


Why is a Simulink Check license checked out when I open a model?
I noticed that when I open certain models, a Simulink Check license ('sl_verification_validation') is immediately checked out. I...

mer än 3 år ago | 1 answer | 0

1

answer

Answered
How do I get a list of a Simulink block's parameters?
This can be accomplished using 'ObjectParameters'. Here is an example from the Simulink Documentation: load_system('vdp') Mo...

nästan 4 år ago | 0

| accepted

Load more