Community Profile

photo

ashwinee jadhao


Active since 2019

Followers: 0   Following: 0

Statistics

  • Knowledgeable Level 1
  • Revival Level 1
  • First Answer

View badges

Feeds

View by

Question


PIL block not build for C2000
Hello, I am working on simulink, want to generate PIL block from the subsystem. whenever I tried to generate PIL block I am get...

ungefär 5 år ago | 0 answers | 0

0

answers

Answered
The PIL simulation reports an error, and the host and target board subdata types do not match. How to solve this problem, I am using the PIL module generated by stateflow, the input and output type of defining the stateflow data is double
You might be using 4byte hardware and sending data of 8byte. Change you data into 4byte. Please give me more details

ungefär 5 år ago | 0

| accepted

Answered
eCAN loading problems to TI C2000 C28x3x card; are example only for Vector hardware
can I use thiosn VN1610 for testing PIL using CAN COMMUNICATION

ungefär 5 år ago | 0

Question


How to use PIL model by using EXTERNAL MODE as CAN instead of serial
Hello, I am using PIL in simulink. Created Plant model running in software and controller model running as PIL block in hardwar...

ungefär 5 år ago | 0 answers | 0

0

answers

Question


Build process completed successfully Error evaluating registered method 'Start' of MATLAB S-Function 'sserialcb' in 'TRANSMIT1/Serial Configuration'. Caused by: Open failed: Cannot connect to the COM6 port. Possible reasons are another application is
I am facing this error while doing SCI transmit data. simulink scenario is shown here. Let me know I am doing anything wrong? ...

ungefär 5 år ago | 2 answers | 0

2

answers

Question


not able to transmit data serially
Hello, I am doing serial communication using SCI block. But it is not transmitting any value. I have used MSO at the SCIB port...

ungefär 5 år ago | 0 answers | 0

0

answers

Question


TMS320F28069M: File C:\ProgramData\MATLAB\SupportPackages\R2018b\toolbox\target\supportpackages\tic2000\registry\thirdpartytools\thirdpartytools_win64.xml not found
I am using c2000 with simulink , my prgram is working good in normal mode but while going to execute in external mode it shows t...

ungefär 5 år ago | 1 answer | 0

1

answer

Question


Error using coder.oneclick.TargetHook/extModeConnect (line 178) Error occurred while executing External Mode MEX-file 'ext_comm': ExtSetTargetPkt() call failed for ExtSendGenericPkt(). Ensure target is still running Error in coder.oneclick.CoderTar
I am doing SCI communication and while debuging code into hardware get successfully debug and then get automatically abort. It g...

ungefär 5 år ago | 0 answers | 0

0

answers

Question


Why not able to set comp port in serial communication block
It giving error - error is occures while evaluating apply callback

ungefär 5 år ago | 1 answer | 0

1

answer

Question


ExtTargetPktPending() call failed while checking for target pkt
I am getting error Error occurred while executing External Mode MEX-file 'ext_comm': ExtTargetPktPending() call failed while...

ungefär 5 år ago | 2 answers | 0

2

answers

Question


Error evaluating registered method 'Start' of MATLAB S-Function 'c2000hostsci_setup' in 'TRANSMIT/SCI Setup'. The following is the MATLAB call stack (file names and line numbers) that produced this error: ['C:\Program Files\MATLAB\R2018b\toolbox\ta
Error evaluating registered method 'Start' of MATLAB S-Function 'c2000hostsci_setup' in 'TRANSMIT/SCI Setup'. The following is t...

ungefär 5 år ago | 1 answer | 0

1

answer

Question


how to execute SCI communication
Hello, I am working on simulink platform and want to communicate two TMS320F28069M LAUNCHPAD using SCI communication. I have us...

ungefär 5 år ago | 1 answer | 0

1

answer

Question


how t generate software interrupt for C2000 in simulink, and connect with states
I am using stateflow in simulink. I want to give software interrupt and as per that interrupt status wants to changes status and...

mer än 5 år ago | 0 answers | 0

0

answers