Stop Simulink simulation base don a variable value
26 views (last 30 days)
Show older comments
Hello:
I want ot know how to stop a simulink simulation automatically when one of the variables reaches a negative value. I will run it through a .m file
Thank you in advance
0 Comments
Accepted Answer
Arnaud Miege
on 20 Jun 2011
Or use a Stop Simulation block. You will also need to construct the logic to create a boolean input signal to the block.
HTH,
Arnaud
0 Comments
More Answers (2)
Fangjun Jiang
on 20 Jun 2011
Add an "Assertion" block into your Simulink model. The block is in the library Simulink>Model Verification. It has the option to stop simulation when assertation fails. You need to construct a simple logic to compare your signal to zero.
0 Comments
See Also
Categories
Find more on Simulink Functions in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!