The following two blocks cannot be connected in series: Block 1: 'A_stator: Asynchronous Machine SI Units' Block 2: 'Series RLC Branch2
56 views (last 30 days)
Show older comments
The following two blocks cannot be connected in series:
Block 1: 'A_stator: Asynchronous Machine SI Units'
Block 2: 'Series RLC Branch2'
The first block, modeled as a current source, cannot be connected in series with the inductive element of the second block. Add a high-value resistance in parallel with one of the two block. You can also specify high-value resistive snubbers if the blocks have a snubber device.You can avoid the use of the snubber by selecting the 'Continuous' simulation type in the Solver tab of the Powergui and deselecting the 'Disable ideal switching' option in the Preferences tab of Powergui block.
2 Comments
Answers (1)
Joel Van Sickel
on 9 Sep 2022
This is a common issue when using specialized power systems. Inductors are modelled as current sources and cannot be in series without an alternative path. The easiest way to do this is to follow the snubber recommendations which means insert a high value resistance between the two blocks, and connect it to ground. You can start with something like a megaohm. This can slow down the simulation. Smaller resistor values will simulate faster but decrease accuracy of the model. Another approach is to use simscape core technology which are the blue components which allow for inductors be in series with each other.
Regards,
Joel