Problem with Fixed time step in simulink

11 views (last 30 days)
When I define a fixed time-step in simulink configuration, and run the simulation, the output has a time-step 10 times more than what I have defined.
For example: defined time-step=0.01 , duration = 20 sec, -----> output data from simulink have 200 data. (It seems that simulink is considered 0.1 instead of 0.01).
Does any body knows why?
  2 Comments
Aquatris
Aquatris on 18 Sep 2018
Do you by any chance have rate transition block or have a block with a sampling time 0.1 (you can have blocks running in different sampling times than the simulation time step)?
Hamid Radmard Rahmani
Hamid Radmard Rahmani on 23 Sep 2018
Many thanks Aquatris. Yes, it was the reason.