Info

This question is closed. Reopen it to edit or answer.

Output Torque is not met request torque ipmsm and FOC plus Torque control

1 view (last 30 days)
inverter output line current peak 494.5 Amps and phase Current peak is 285 Amps. Actual id -94 Amps actual Iq is 266.3 Amps. Ld (D Axis inductance) is 0.0943e-3 Henry. Lq (Q Axis inductance) is 0.1321e-3 Henry. Number of poles is 10. Phase Resistance (Rs) is 0.01125 Amps. inertia (Jm) is 0.00277 (Kg*m^2). Rotor Damping is 0.0004924 (N*m/(rad/s)). connection is delta. Magnetic Flux linkage (Web) is 26.82e-3 (Weber). request torque is 60 Nm. But output torque is 47 Nm. When I calculate manually, output torque is 60 Nm. The torque equation is used for ipmsm delta connection three phase n channel mosfet inverter are used. When I calculate manually the result is 60 NM. But when i check in pmsm block, output torque is 47 Nm. I cannot increase Iq to 323.6 A, It is automatic and close loop concept.

Answers (0)

This question is closed.

Communities

More Answers in the  Power Electronics Control

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!