Load Flow Analysis employing Solid State Transformer

11 views (last 30 days)
Anand
Anand on 17 Feb 2022
Commented: Feng on 24 Oct 2025 at 1:03
This is a simple 3 bus network where Solid state transformer is connected between bus 1 and bus 3. The model of SST is working perfectly but whenever I run the load flow, bus 2 (loads connected at SST) is being ignored by prompting a message 'The following subnetworks have been ignored because they contain no swing bus'. I don't know whether it is due to detail model of SST employing multiple power electronic device in between or due to High Frequency transformer in between, does anybody have idea regarding this ? Thanks !
  1 Comment
Feng
Feng on 24 Oct 2025 at 1:03
Where can we download the model to have futher analysis? Thanks!

Sign in to comment.

Answers (1)

Sabin
Sabin on 30 Dec 2022
Edited: Sabin on 30 Dec 2022
I believe the main issue here is level of fidelity of the SST. It looks like detailed power electronics and transformer are employed but that’s a bit in contradiction with the definition of load flow analysis. I suggest implementing the SST in a more abstract way.

Products


Release

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!