problems with Block "Wind Turbine Induction Generator (Phasor Type)"

1 view (last 30 days)
I am a master student and my thesis is in renewable electrical power and I am using Matlab R2018b. When I am using the block “Wind Turbine Induction Generator (Phasor Type)” I am getting the max output real power P = 0.45 p.u. (I was expecting to have P =1.0 p.u.) and a zero reactive power Q at base wind speed. And the system is very sensitive to any change in the load or the excitation capacitors. You can email me to send you the model file and a photo of the simulation results.
Thanks in advance,
Engineer / Ibrahim Athamnah
2019979009@ses.yu.edu.jo

Answers (2)

Sabin
Sabin on 22 Dec 2022
It is probably due to parameterization or the way the design of the model is done. Without a model not easy to understand the issue though. Probably best to check the power_wind_ig example as a starting point.

Ibrahim Athamnah
Ibrahim Athamnah on 23 Dec 2022
Thanks Sabin Carpiuc for your reply. But unfortunately I tried this example since long time but still the same problem !!