How to delete I/O linearisation points in a simulink model from the workspace?

2 views (last 30 days)
For example, I set 2 linear analysis points as :
sys = 'watertank';
load_system(sys);
open_system(sys)
sys_io(1)=linio('watertank/PID Controller',1,'input');
sys_io(2)=linio('watertank/Water-Tank System',1,'openoutput');
setlinio(sys,sys_io);
linsys=linearize(sys,sys_io)
Is there any command to clear these 2 points from simulink model?
Hear from you people
Thanks
Yashvin

Accepted Answer

Arkadiy Turevskiy
Arkadiy Turevskiy on 12 Aug 2014
sys_io=[ ];
setlinio(sys,sys_io);