usb 6008 error message

6 views (last 30 days)
mado
mado on 4 Feb 2014
Answered: Walter Roberson on 5 Feb 2014
% when i used this daq and i changed the channel id to ai4 up to 7 it gives this error from ai0 to ai3 it works fine
% NI Error -200077:
Requested value is not a supported value for this property. The property value may be
invalid because it conflicts with another property.
Property: DAQmx_AI_Min
Requested Value: -20.0
Valid Values Begin with: -10.0
Valid Values End with: 10.0
%
Channel Name: Dev1/ai4
Task Name: _unnamedTask<44B>
Status Code: -200077

Answers (1)

Walter Roberson
Walter Roberson on 5 Feb 2014
A patch is given there. The problem was fixed as of R2012b.

Categories

Find more on Data Acquisition Toolbox Supported Hardware in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!