Sample and Hold
Sample first input and hold its value based on value of second input
Library
Simscape / Electrical / Specialized Power Systems / Control
Description
The Sample and Hold block outputs the In input
signal as long as S input signal is true. The block
holds the output when the S input signal becomes
false.
Parameters
- Initial condition
 Specify the initial value of the output. Default is
0.- Sample time
 Specify the sample time of the block, in seconds. Set to
0to implement a continuous block. Default is0.
Inputs and Outputs
InThe signal.
SThe control signal, which must be a Boolean.
OutThe sampled signal.
Characteristics
| Direct Feedthrough | Yes | 
| Sample Time | Specified in the Sample Time parameter | 
| Scalar Expansion | Yes | 
| Dimensionalized | Yes | 
| Zero-Crossing Detection | No | 
Examples
The power_SampleAndHold example shows the operation of the Sample and Hold
            block.
The model sample time is parameterized with the variable Ts (default value Ts = 50e-6). To simulate a continuous Bistable block, specify Ts = 0 in the MATLAB® Command Window.
Version History
Introduced in R2013a