Check safety-related diagnostic settings for model referencing
Check ID:
mathworks.hism.hisl_0310
Check model configuration for diagnostic settings that apply to model referencing and that can impact safety.
Description
This check verifies that model diagnostic configuration parameters pertaining to model referencing are set optimally for generating code for a safety-related application.
Available with Simulink® Check™.
Results and Recommended Actions
Condition | Recommended Action |
---|---|
The diagnostic that detects port and parameter mismatches during
model loading and updating is set to
none
or warning . If undetected, such mismatches
can lead to incorrect simulation results because the parent and
referenced models have different interfaces. | Set Port and parameter
mismatch on the Diagnostics > Model Referencing pane in the Configuration Parameters dialog box or set the
parameter ModelReferenceIOMismatchMessage to
error . |
The diagnostic that detects whether To Workspace or
Scope blocks are logging data in a referenced model
is set to
none
or warning . Data logging is not supported for
To Workspace and Scope blocks in
referenced models. | Set Unsupported data logging on the Diagnostics > Model Referencing pane in the Configuration Parameters dialog box or set the
parameter ModelReferenceDataLoggingMessage to
error .To log data, remove the blocks and log the referenced model signals. For more information, see Override Signal Logging Settings with Signal Logging Selector. |
Action Results
Clicking Modify Settings configures model diagnostic settings that apply to model referencing and that can impact safety.
Capabilities and Limitations
Does not run on library models.
Does not allow exclusions of blocks or charts.
Revision History
R2024a - Removed configuration parameter
Invalid root Inport/Outport block connection
(ModelReferenceIOMsg
). To diagnose and fix invalid connections,
use Model Advisor check Check for invalid root input and output port connections (ID:
mathworks.hism.hisl_0079
) instead.